TERMINAL BOARD

Sul lato sinistro (tolto il coperchio protettivo avvitato A
terminal board is mounted just above the electronic
board, on the left-hand side (remove the protective
cover fastened with two screws).
The terminal board includes low and high voltage.
Examples of possible connection configurations are
shown below.
The poles are numbered on the product as described below:
No.
POSSIBLE CONNECTIONS
POLES
1/2
NTC probe/room thermostat
Home automation input. This input receives all
3/4
home automation contacts
External solenoid valve, external boiler permissive,
5/6 /7
remote alarm, any device that manages a potential-
free contact
12
8/9/10
Electrical connection for booster/secondary pump
TERMINAL BOARD
NOTES
Non-standard supplied
Configuration in system/technical menu
5=black - normally open (NA)
6=red - normally closed (NC)
7=white - common
"8=brown / live
9=blue / neutral
10=yellow-green / earth"
INSTALLER