8.3 MODBUS MEMORY MAP
Table 8–6: 745 MEMORY MAP (Sheet 24 of 57)
GROUP
ADDR
(HEX)
FLEXCURVES
11AD
continued
11AE
11AF
11B0
11B1
11B2
11B3
11B4
11B5
11B6
11B7
11B8
11B9
11BA
11BB
11BC
11BD
11BE
11BF
11C0
1210
1260
126F
VOLTAGE
1270
INPUT
1271
1272
1273
8
1274
127F
AMBIENT
1280
TEMP
1281
1282
1283
1284
1285
1286
8-40
DESCRIPTION
FlexCurve A Delay at 11.0 × PKP
FlexCurve A Delay at 11.5 × PKP
FlexCurve A Delay at 12.0 × PKP
FlexCurve A Delay at 12.5 × PKP
FlexCurve A Delay at 13.0 × PKP
FlexCurve A Delay at 13.5 × PKP
FlexCurve A Delay at 14.0 × PKP
FlexCurve A Delay at 14.5 × PKP
FlexCurve A Delay at 15.0 × PKP
FlexCurve A Delay at 15.5 × PKP
FlexCurve A Delay at 16.0 × PKP
FlexCurve A Delay at 16.5 × PKP
FlexCurve A Delay at 17.0 × PKP
FlexCurve A Delay at 17.5 × PKP
FlexCurve A Delay at 18.0 × PKP
FlexCurve A Delay at 18.5 × PKP
FlexCurve A Delay at 19.0 × PKP
FlexCurve A Delay at 19.5 × PKP
FlexCurve A Delay at 20.0 × PKP
FlexCurve B (80 registers: see FlexCurve A)
FlexCurve C (80 registers: see FlexCurve A)
Reserved
Reserved
Voltage Sensing
Voltage Input Parameter
Nominal VT Secondary Voltage
VT Ratio
Reserved
Reserved
Ambient Temperature Sensing
Ambient RTD Type
Average Ambient Temperature for January
Average Ambient Temperature for February
Average Ambient Temperature for March
Average Ambient Temperature for April
Average Ambient Temperature for May
745 Transformer Management Relay
RANGE
STEP
UNITS
VALUE
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
0 to 65000
1
ms
---
---
---
---
---
---
---
---
---
---
---
---
60.0 to 120.0
0.1
V
1 to 5000
1
:1
---
---
---
---
---
---
–50 to 125
1
°C
–50 to 125
1
°C
–50 to 125
1
°C
–50 to 125
1
°C
–50 to 125
1
°C
8 COMMUNICATIONS
FORMAT
FACTORY
CODE
DEFAULT
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
F1
0 ms
---
---
---
---
F30
0 = Disabled
F63
0 = W1 Van
F2
1200 = 120.0 V
F1
1000:1
F30
0 = Disabled
F41
0 = 100W Pt
F4
20°C
F4
20°C
F4
20°C
F4
20°C
F4
20°C