Save translations

To synchronize the main server's translations with the LSP:
1. Log in to the main server's SAT interface.
2. At the SAT prompt type save translation lsp and press Enter.
Look for "Success" in the Command Completion Status section.
3. Logoff the system.
4. Release alarm suppression when prompted.
Note:
The time that it takes to synchronize the files with the LSP depends on the
Note:
system and network resources.
5. Verify that the translations have synchronized with the LSP at the main server's SAT
interface by typing list survivable-processor and press Enter.
6. Ensure that this LSP server is listed and registered. Look for "Y" in the Reg(istered) column.

Final replacement tasks

Perform the following tasks to complete the server or hard drive replacement:
1. At the Maintenance Web Pages select Server > Status Summary and check the overall
health of the system.
2. Run the port check tool:
a. At the server command line type portcheck and press Enter.
b. Select Server Interface (ethX) test (#4), and press Enter.
c. Ensure that the interfaces listed In the Link column are up.
3. Resolve any alarms (Alarms > Current Alarms).
4. Save translations (Data Backup/Restore > Backup Now).
5. Set backup schedules (Data Backup/Restore > Schedule Backup).
6. At the server command line type productid -p product_id, where product_id is the
product ID you received from the customer or the ART tool.
7. Re-enable alarm origination:
a. At the server command line type almenable -d b -s y and press Enter, where: