4.4.1 Cleaning/replacing UV low pressure
lamps in the lower section
1
Removal
Danger of burns!
Make sure that the UV low pressure lamps have cooled
down.
•=
Disconnect sunbed and secure against
accidentally being switched on again (refer to
section 4.3).
•=
Unlock the sunbed base with an Allen key at the
trough lock (catch A).
•=
Fold the sunbed base up until the supports lock
in.
•=
Remove the intermediary panel (1).
3
04059 / 0
•=
Remove the lamp covers (3) at the head and foot
ends.
•=
Remove the UV low pressure lamps (4) and
change, cleaning with a damp cloth if necessary.
4
04033 / 0
Maintenance
Installation
•=
Insert the UV low pressure lamps with the
lettering towards the foot end and rotate by 90
degrees (1/4 turn) until they catch. The lettering
is on the visible side of the UV low pressure
lamps. Do not align the lamps by the lettering.
•=
For further assembly proceed in reverse order.
Note!
Unlock the supports for closing the sunbed base (1) by
lifting the panel.