Summary of Contents for ergoline Prestige 1150 Intelligent Performance
Page 1
P R E S T I G E 1 1 5 0 I N T E L L I G E N T P E R F O R M A N C E OPER ATIN G IN S T RUCT I O NS...
Page 3
Operating instructions Translation of the original operating instructions Ergoline PRESTIGE Series PRESTIGE 1150 INTELLIGENT PERFORMANCE PRESTIGE 1150 INTELLIGENT PERFORMANCE AF & AROMA 1020141-00 / en / 10.2018...
Page 4
Legal notice Legal notice Manufacturer: JK-Products GmbH Köhlershohner Straße 60 53578 Windhagen GERMANY Tel.: +49 (0) 22 24 / 818-140 Fax: +49 (0) 22 24 / 818-166 Customer service / JK-International GmbH, Technical service Division JK-Global Service (Spare part orders for Köhlershohner Straße 60 components): 53578 Windhagen...
Table of contents Table of contents Safety instructions and warnings ..........6 General ................... 6 1.1.1 Definitions ..................6 1.1.2 Symbol explanation ................. 7 Intended use ................... 8 Foreseeable misuse ................ 8 Tanning safety information .............. 9 1.4.1 Prohibited usage ................9 1.4.2 Important notes ................
Page 6
Table of contents Functions ..................33 Start ....................34 Coupling with Bluetooth® devices ..........35 AUX (musik) .................. 37 Cleaning and maintenance ............38 Safety instructions when undertaking cleaning or maintenance work ........38 Faults..................... 39 Cleaning ..................39 4.3.1 Cleaning the surfaces ..............
Page 7
Technical data ................71 Power, connection rating and noise level ........71 Dimensions ................... 72 Lamp sets ..................73 5.3.1 PRESTIGE 1150 INTELLIGENT PERFORMANCE / PRESTIGE 1150 INTELLIGENT PERFORMANCE AF & AROMA ......73 Spare parts and accessories ............74 Appendix ..................75 JK timer controls ................
Safety instructions and warnings Safety instructions and warnings To ensure safe operation of the device, it is necessary to read the following safety instructions and warnings carefully and comply with them. The safety instructions summarized here are repeated in the corresponding chapters, where necessary.
Safety instructions and warnings 1.1.2 Symbol explanation The following types of safety notices are employed in these operating instruc- tions: DANGER! Type and source of hazard This safety notice indicates the existence of a direct danger to body and life. DANGER! Type and source of hazard This safety notice warns of dangers to body and life which...
Safety instructions and warnings Intended use This device serves the purpose of cosmetic tanning for one adult person with skin suitable for tanning. Additional information is available on pages 11 and 28. This device is intended only for commercial use and not for private use. Some people are not permitted to use the device, see page 9.
Safety instructions and warnings Tanning safety information 1.4.1 Prohibited usage DANGER! UV radiation Danger of skin and eye injuries or skin diseases! – Please observe the following instructions. The following people may not use the device: People under 18 years of age ...
Page 12
Safety instructions and warnings Increasing tanning requires increased exposure time (= radiation time) or after a certain degree of tanning has been achieved, increased tanning is not possible. However, the radiation time may not be extended as desired within the scope of the permissible radiation doses! Therefore, only a cer- tain level of final tanning, which depends on the skin type, can be achieved without endangering your health.
Safety instructions and warnings 1.4.3 Skin type descriptions DANGER! Burns and long-term damage! People with skin type I may not use the tanning device. The following applies to people with skin types II, III and IV: – Observe the tanning times. –...
The tanning dosage of 3 kJ/m² per tanning period should not be exceeded. PRESTIGE 1150 INTELLIGENT PERFORMANCE: UV low pressure lamps ERGOLINE TREND DYNAMIC 160W E40 1508551-.. UV low pressure lamps TREND 8W E29 1508223-.. Number of tanning...
Safety instructions and warnings Safety instructions and warnings 1.5.1 Operator's obligations As the operator you are responsible for providing clear operating, cleaning and maintenance instructions and ensuring the intended use and the proper operation of the device by means of training and instruction for the personnel. Your operating instructions must enable the safe use and safe operation of the device and take into account the characteristics and expertise of your company and also the national work safety and environmental protection...
Page 16
Do not set up and operate the device on the transport pallet! Data regarding the air supply and ventilation planning is available in the plan- ning manual (www.ergoline.de, available in English and German). You can also obtain this data from your dealership or the customer service department (see page 2).
Page 17
Safety instructions and warnings Setup location WARNING! Salty air! Contaminated air! Device damage due to corrosion of the housing and electri- cal components. – Do not install the device at swimming pools. – Do not operate the device in locations with aggressive environmental conditions (e.g.
Safety instructions and warnings 1.5.5 Commissioning DANGER! Damaged mains power cable! Danger to persons through electric shock or burns. – Only the manufacturer or specialist companies are permitted to replace the mains power cable. Initial commissioning will be undertaken by the manufacturer's own service personnel or by an authorized service company.
Safety instructions and warnings 1.5.7 Decommissioning The device must be disconnected from the power supply in order to tempo- rarily or permanently decommission it. You must abide by the legal disposal requirements when permanently de- commissioning the device. 1.5.8 Storage Store the devices in a dry location with a stable temperature.
Safety instructions and warnings The components and devices are labelled with the following symbol: The device will, if requested, be properly disposed of by the JK Corporate Group. This service is available free of charge. Your partner agency or dealer will be happy to advise.
Safety instructions and warnings quired audio CDs, MCs, audio DVDs etc. may be made. The source media (original media) must be retained and may not be used simultaneously. Further details can be found in the information brochure 'Audio Guide' availa- ble on the Internet at http://www.jk-globalservice.de .
Safety instructions and warnings Signs and stickers on the device Danger area warning signs and important information about components are attached to the device. The signs shown below are examples. Ensure that the warning signs are always clearly recognisable and legible. Any missing warn- ing signs or stickers must be replaced.
Page 23
Safety instructions and warnings 1: EU warning sticker (1012638-..) This sticker also includes the language form 1504231-.. (see Technical Doc- umentation folder). 2: 'No export USA/Canada' sticker (84829-..) The sticker is mounted on the bottom edge at the front of the bed base. 3: 'Only use original spare parts' sticker (801026-..) The sticker is mounted on the bottom edge at the front of the bed base.
Page 24
Safety instructions and warnings 5: Maintenance instruction sticker (800701-..) 6: Exhaust air warning sticker (843319-..) The sticker is mounted in the centre of the rear panel. 7: Type plate The name plate is attached to the interior side of the canopy. It contains important information for identifying the device (e.
Page 25
Safety instructions and warnings Stickers 8 - 11 are mounted beneath the bed base. 8: Air conditioning sticker (1002243-..) 13435 / 0 The sticker is mounted on the air conditioning. 9: Ballast support warning sticker (1013941-..) The sticker is mounted on the power unit support. 10: Controller connections sticker (1013863-..) The sticker is mounted on the controller support.
Safety instructions and warnings Warranty On behalf of customers who have purchased a tanning device for private or commercial utilisation from one of the JK-International GmbH sales partners, JK-International GmbH accepts liability for any defects on the tanning device that arise in accordance with the following regulations; wearing parts such as high pressure lamps (bulbs), low pressure lamps (tubes) and starters and consumables (e.g.: Aqua-System, Aroma-System) as well as the acrylic glass panels are not covered by the warranty...
Description Description Scope of delivery Tanning device Service kit including an Allen-key and suction cup for filter panels Air conditioning system Connecting lead Protective goggles Technical documentation (folder with instructions, brochures for error codes and default settings and additional documentation) The low pressure UV lamps are delivered and packaged separately.
Description Accessories (optional) 18367 / 0 1. Central exhaust air socket (optional) 2. Shoulder tanner with sound system Functional description The primary technical components of a tanning device are an artificial source of UV radiation, a variety of filters and reflectors as well as a mechanical structure with a defined active surface.
Operation Operation User safety information DANGER! UV radiation Danger of skin and eye injuries or skin diseases! – Please observe the safety instructions and warnings in chapter 1. Danger of hearing damage! Using earphones or headphones at high volume can result in permanent hearing damage.
Page 31
Operation Contact lenses in the tanning device? The answer is: Yes! Like any other tanning device user, contact lens wearers should also wear special protective goggles which protect the eyes against UV radiation. To guarantee better protection, wearers of spectacles and con- tact lenses can ask their optician for exchange contact lenses with UV protec- tion.
Operation Control panel 1. START/STOP button 2. Navigation unit 3. Climatronic/air conditioning pictogram 4. Body fan pictogram 5. Face fan pictogram 6. Display – Functions … 7. Facial tanner pictogram 8. AROMA SYSTEM pictogram 9. AQUA SYSTEM pictogram 10. Volume pictogram 11.
Operation 3.3.2 Navigation Via the Control Center the most important settings can be made before start- ing the device. During the tanning session, functions may be activated or deactivated via the control panel inside the device. Navigation unit - Control Center The Control Center enables comfortable access to special functions.
Operation Functions Function Pictogram selection / Description / Display Information Button sequence 1. UV lamps START/STOP The tanning time continues to Switches the UV lamps on / run if the UV lamps are off during the tanning session switched off during tanning session.
Operation Function Pictogram selection / Description / Display Information Button sequence 11. Audio System Select audio system: Selecting an audio system A: own music, MP3 player, automatically deactivates the Smartphone or Bluetooth® Connect others. B: select title, 'Music' SD-card In Bluetooth® mode, C: studio channels, externally can be used to choose music connected system (e.g.
(e.g.) from their smartphone. The operation is car- ried out during the tanning session conveniently via the Control Center. NOTE: Ergoline cannot guarantee full compatibility with all Bluetooth® devices. Before coupling a device with this system, read the user manual to find out more about the Bluetooth®...
Page 38
Operation Activate Bluetooth® Connect on the Control Center – Press the Bluetooth® symbol on the Control Center. Successful coupling on the Control Center. NOTE: Start with the audio player music on the Bluetooth® MP3 player. Successful coupling on the Control Center in standby mode. NOTE: When successfully coupled, the Bluetooth®...
Operation AUX (musik) DANGER! Danger of hearing damage! Using earphones or headphones at high volume can result in permanent hearing damage. – Do not set the volume too high. The user can connect her/his own private MP3 player or smartphone to the device, if the audio system accessory is fitted.
Cleaning and maintenance Cleaning and maintenance Safety instructions when undertaking cleaning or maintenance work DANGER! Electricity throughout entire device! Personnel danger due to electric shock or electric burns. – Before beginning work, disconnect all of the power connections from mains voltage. –...
Cleaning and maintenance Faults Error codes are output to the display to simplify troubleshooting: If a fault occurs, the error code appears in the display. If several faults occur, the fault messages are displayed alternately. The error is acknowledged by pressing theSTART/STOP-button. ...
Cleaning and maintenance 4.3.1 Cleaning the surfaces Acrylic glass surfaces WARNING! Do not rub with a dry cloth – danger of scratching! Failure to comply invalidates any warranty claims. – For the fast, hygienic and proper cleaning of acrylic glass surfaces, use specially developed cleaning agents.
Cleaning and maintenance Cleaning plan Component Interval Activity See page Adjustable air nozzles Cleaning and disinfection Acrylic glass panel Cleaning and disinfection Operating handle Cleaning and disinfection Display unit Cleaning and disinfection Control Center Cleaning and disinfection Protective goggles Cleaning and disinfection AUX cable Cleaning and disinfection Condensation tank...
Cleaning and maintenance Component Interval Activity See page Filter Remove and clean filter 4, 10 Filter mats Remove and clean filter 65, 64 Air intake openings Clean NOTE: After every tanning session, when the cleaning mode is activated in the Control Center and the run-on time of the device fan has finished, cleaning must be confirmed by pressing the START/STOP button.
Cleaning and maintenance 4.5.1 Acrylic glass WARNING! Cosmetics may cause cracks to form on the surface! Over the long-term cosmetics or sunscreens cause damage (e.g. crack formation on the surface). – Ensure that cosmetics and sunscreens are removed before tanning. The acrylic glass panels for the tanning devices are produced of acrylic glass developed especially for this application.
Page 46
Cleaning and maintenance 18042 /2 Component Interval Activity See page AQUA SYSTEM Replace 6a-6b AROMA canister Replace UV high pressure lamps, Replace shoulder tanner UV-B-low pressure lamp, Replace facial tanner UV high pressure lamps, Replace facial tanner UV low pressure lamp, Replace base UV low pressure lamp,...
Page 48
Cleaning and maintenance Maintenance performed by authorized, trained and qualified staff WARNING! Danger to persons from maintenance work that has not been carried out! If maintenance work is not carried out, it can lead to material damage or personal injuries! –...
Cleaning and maintenance Cleaning and maintenance work prep- aration 4.7.1 Service kit 1. Allen key 2. Suction cup for filter panels, acrylic glass panel and canopy panel 3. Scratch prevention for the entry area (support cushion for the canopy) The service kit is fitted on the inside of the front panel. –...
Cleaning and maintenance – Use the cushion as scratch prevention when opening the canopy panel. 4.7.2 Lift up the acrylic glass panel and remove the partition – Lift the acrylic glass panel up to the stop. The acrylic glass panel will automatically be held in place. –...
Cleaning and maintenance The assembly is the same process in reverse order. When assembling the device please note: – You must ensure that the recesses are at the foot end when you fit the partition. – Lift the partion up slightly and then close it. 4.7.3 Remove the canopy panel –...
Cleaning and maintenance The assembly is the same process in reverse order. When assembling the device please note: – Support the canopy panel with one hand so that it does not fall down. – Re-lock the locks: first the lock in the middle, then the outer locks. 4.7.4 Remove the side section panel –...
Cleaning and maintenance 4.7.5 Open the bed base – Press the bed base gently downwards. – Release the lock at the head end. – Lift up the bed base. – Close the bed base. You should hear the bed base click into place. 10/2018 1020141-00 Operating instructions –...
Cleaning and maintenance Instructions for replacing the lamps DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. The lamp's UV effect and therefore the tanning effect decrease over time.
Cleaning and maintenance 4.8.1 Changing the chip card DANGER! Danger of being burnt by an over-powered lamp! If the old chip card is left in the device, the new lamp set will be run at too high power and the user may suffer heavy burns! –...
Cleaning and maintenance 4.8.2 Low pressure lamps DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. Replace faulty UV low pressure lamps immediately. ...
Cleaning and maintenance 4.8.3 Starter Replace faulty starters immediately. You can recognize a faulty starter by the blackened ends of the (UV) low pressure lamps or when the (UV) low pressure lamps can no longer be start- Operating a (UV) low pressure lamp with a faulty starter significantly shortens its service life.
Cleaning and maintenance 4.8.4 High pressure lamps and filter panels UV high pressure lamps are used in the facial tanner and the shoulder tanner. DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps and filter panels or cleaning reflectors.
Page 59
Cleaning and maintenance – Only utilize original UV lamps. – Only touch new lamps in the handling zone. – Test the function of the safety switch. The safety switch ensures that the device switches off in the event of a faulty filter panel.
Cleaning and maintenance Cleaning or replacing UV lamps in the base – Lift up the acrylic glass panel and then remove the lamp covers and the partition: see page 48. Replacing lamps: see page 54. Changing the chip card: see page 53. The assembly is the same process in reverse order.
Cleaning and maintenance When assembling the device please note: – Insert and tighten the screws 4.11 Cleaning or replacing UV lamps and filter panels in the canopy – Removing the canopy panel: see page 49. The following components listed in the maintenance plan are fitted in the canopy: 1.80 m UV low pressure lamps ...
Page 62
Cleaning and maintenance – Remove the ninth low pressure lamp in the canopy vertically so that you can access the facial tanner's low pressure lamp starters. Replacing lamps: UV low pressure lamps: see page 54. UV high pressure lamps and filter panels: see page 56. Replacing starters: see page 55.
The device might be damaged. – Only Ergoline ULTRA UV high pressure lamps (1500384-..) are to be fitted in the shoulder tanner. Each of the high pressure lamps in the shoulder tanner is fitted with 2 different filter panels.
Page 64
Cleaning and maintenance – Use the suction cup to lift the upper filter panel. – Pull out the holder. – Use the suction cup to remove the two filter panels. WARNING! Do not interchange filter panels! The shoulder tanner is fitted with different filter panels. a) Ultra Performance 912 (blue), order no.
Cleaning and maintenance 4.13 Cleaning the filter in the base – Opening the bed base: see page 51. – Remove the filters. – Cleaning the filters when moist or dry. Dry cleaning: Vacuum cleaner (depending on the degree of soiling) Moist cleaning: Use water and detergent or put in a dish-washer WARNING! The device may be damaged by moisture!
Cleaning and maintenance 4.14 Cleaning the canopy filter mats – If necessary, cover the canopy in order to prevent the paint from being scratched. – Remove the filter mats fitted at the back of the canopy. – Dry or moist clean the filter mats or replace with new ones. Dry cleaning: Vacuum cleaner (depending on the degree of soiling) Moist cleaning: Water and detergent –...
Cleaning and maintenance 4.15 Air conditioning: Empty the conden- sation tank and clean the filter WARNING! Damage to the device through soiled filters and cooling fins! Regularly check the filter grill and cooling fins on the air conditioning system and clean if necessary. We recommend using the specially manufactured fin comb, art-no.
Page 68
Cleaning and maintenance – Remove the filter from the holder. – Cleaning the filters when moist or dry. Dry cleaning: Vacuum cleaner (depending on the degree of soiling) Moist cleaning: Water and detergent – Do not clean in the dish-washer! –...
Page 69
Cleaning and maintenance WARNING! The device may be damaged by moisture! The cleaned filters must be dry before they are replaced. – Refit the cleaned and dried filters. – Ensure that the filters are correctly positioned in the holder. – Attach the cover.
Cleaning and maintenance 4.16 AQUA / AROMA system maintenance The AQUA SYSTEM function sprays a fine mist of AQUA SOLAR WITH SKIN+ ADDITIVE into the interior of the device for body cooling (see 'AQUA SYSTEM PRODUCT INFORMATION', order no. 1011201-..). DANGER! Customer health hazard! Water that has been contaminated with bacteria can cause...
Cleaning and maintenance – Unscrew the lid on the new canister. – Write the date on the canister. – Fit the canister in the holder. – Close the bed base. You should hear the bed base click into place. 4.16.2 Replacing the AQUA SYSTEM canister –...
Cleaning and maintenance – Screw the lid with the hose onto the new canister. – Push the hose well down so that it touches the bottom of the canister. – Put the canister back in the device. – Close the bed base. You should hear the bed base click into place. Venting NOTE: To ventilate, access to the Professional Setup Manager in...
Technical data Technical data Power, connection rating and noise level PRESTIGE 1150 INTELLIGENT PERFORMANCE / PRESTIGE 1150 INTELLIGENT PERFORMANCE AF & AROMA Power consumption rating with air conditioning: 15700 W Rated frequency: 50 Hz Rated voltage: 400-415 V 3N~ 230-240 V ~3...
Technical data Dimensions B+ = 1545 mm H = 1491 mm B = 1521 mm H1 = 1955 mm B- = 1516 mm H2 = 1106 mm B1 = 953 mm H4 = 450 mm B2 = 205 mm H5 = 56 mm L = 2380 mm H6 = 1879 mm L1 = 2200 mm...
MANCE AF & AROMA Lamp set (UV-typ 2) Number Description Length Power Control Order-no. UV high pressure lamps Ergoline ULTRA 420 W 420 W / 360 W / 12645-.. 260 W / 0 W Filter panels Ultra Performance 842 H TREND 1005802-..
Technical data Spare parts and accessories Number Description Order-no. Partition 1500339-.. Filter 52104-.. Filter mat – Filter 51937-.. Filter 55567-.. AQUA SYSTEM, 6000 ml 1010506-.. AROMA, 100 ml CABIN 701358-.. RELAX 701357-.. Filter mats 843150-.. Protective goggles 84592-.. AUX cable 1001855-..
Appendix Appendix JK timer controls The following coin modules/time control systems can be utilized with the PRESTIGE series devices. MCS III plus Order no.: 500000456 04144 / 0 Studiopilot Order no.: 34009900 Equivalence key range Example for calculating the equivalence key range (1), see the lamp configuration sticker: If the equivalence key of the lamp with which the device has been equipped during the type approval is...
Appendix 100–R–(35-47)/(2.7-3.7) 6.2.1 Description of the equivalence keys for UV fluorescent lamps The equivalence key for UV fluorescent lamps for tanning that is represented in detail in the IEC 61228 and that is marked on the lamp in a readable and permanent manner, is described in the following.
Page 84
I N T E L L I G E N T P E R F O R M A N C E J K - I N T E R N A T I O N A L G M B H Koehlershohner Strasse 60 53578 Windhagen/GERMANY Phone: +49 (0) 2224/818-0 Fax: +49 (0) 2224/818-500 Internet: www.ergoline.de E-Mail: info@ergoline.de...
Need help?
Do you have a question about the Prestige 1150 Intelligent Performance and is the answer not in the manual?
Questions and answers