Low Pressure Lamps - ergoline ESSENCE 440 SMART POWER 200 VIBRA SHAPE Operating Instructions Manual

Hide thumbs Also See for ESSENCE 440 SMART POWER 200 VIBRA SHAPE:
Table of Contents

Advertisement

Cleaning and maintenance
46/60
4.8.1

Low pressure lamps

Replace faulty UV low pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
Turn 90° and carefully remove from the socket.
UV low pressure lamps possess a reflector which directs the light out-
wards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
Push the pins vertically into the socket from above.
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the user).