The success of the Ergoline GmbH is no fluke but the result of consistent satisfaction of customer wishes and requirements. More than 25 years experience give Ergoline a head start in know- how for ever more perfection in technical production and quality assurance. A...
Instructions for Use Ergoline Classic 475 Order No.: 86938 / Index ”_” / en / Edition 03.2001 Equipment number Please enter the equipment number here. This makes handling easier for after-sales service, repairs and spare parts inquiries (refer to section 2.1).
Page 4
Foreword Dear Customer, In selecting an Ergoline professional sunbed you have acquired a high-performance technical appliance featuring advanced technology. We have manufactured your professional sunbed with the utmost care and precision and it has been subjected to numerous quality and safety inspections to guarantee trouble-free and safe and reliable operation.
Page 5
Introduction •= Meaning of the symbols Please read and observe the information in these instructions for use. You will avoid accidents, retain the manufacturer guarantee and acquire a fully functional and ready to Hazard warnings: use professional sunbed. •= This sunbed is designed and built exclusively for the intended purpose. Any use above Danger! and beyond this will be construed as improper use.
Contents General Maintenance 1.1 Directives 4.1 Maintenance intervals 1.2 Intended Use 4.2 Care and maintenance tasks, Cleaning 1.3 Export 4.3 Disconnecting the sunbed from the mains/preventing from switching on 1.4 Safety 4.3.1 Disconnecting from mains 1.5 Care and Maintenance 4.3.2 Preventing from switching on again 1.6 General tanning instructions 4.4 Replacing and cleaning lamps...
Page 7
Contents After-sales service Appendix 8.1 Environmental declaration 8.1.1 The JK Corporate Group 8.2 Environmental regulations 8.2.1 Disposing of UV low pressure lampsand batteries 8.3 Ergoline Sound System 8.3.1 Important information on use (GEMA) Warranty EU Conformity Index of keywords...
General General 1.1 Directives 1.2 Intended Use This professional sunbed has been manufactured in conformity with the following •= This professional sunbed is for tanning one adult at a time. directives: •= The sunbed base is designed for a maximum weight of 135 kg. •= EC Directive ”Electromagnetic compatibility””...
The professional sunbed has to be controlled by the Ergoline MCS-VI coin •= Only genuine Ergoline parts of the same type should be used. The use of other device or a compatible timer (in conformity with the standard EN 60335-2-27).
Anyone who can get a tan in natural sunshine. People with sensitive skin will tan more aggressive rays of the sun. Rays of this type are present in Ergoline sunbeds in easily and without risk of burning because the amount of radiation can be accurately extremely small quantities so that this type of protection is quite unnecessary.
General 1.6.2 General safety instructions 1.7 Recommended tanning times Carefully read Ergoline’s tips for proper tanning. Risk of injury to skin and eyes •= Do not use the professional sunbed if the timer is faulty or the filter panels are •=...
Page 13
Maximum number of tanning sessions per year (=15 kJ/m (=15 kJ/m (=15 kJ/m Model Equipment type Ergoline CLASSIC 475 turbo power UV type 4 UV type 3 UV type 4 UV type 3 UV type 4...
Description Description 2.1 Equipment type 2.1.1 Name plate 2.1.2 Number plate 2.1.3 The position of the name plate / number plate " Typ Fabr. Nummer I Type Serial-Number Spannung Voltage Lstg Input UV-Typ 511 35 100 546573 400-415V 3N~ 50Hz 13500 W 04010 / 0 00219 / 1...
Description 2.3 The phases of the tanning 2.4 Settings 2.5 Display programme The tanning programme of the equipment includes •= tanning time •= cooling time Tanning time After the warm-up phase is over, all of the equipment components are ready for operation and the selected tanning time begins.
Description 2.6 Decorative lighting 2.7 Sound system 04029 / 0 04004 / 0 04005 / 0 •= The lighting effect (1) on the sunbed is activated as The sound system has a multi-channel input. In the setting mode, information concerning soon as the equipment is started up.
Operation Operation 3.1.1 Switching on UV Lamps 3.1.2 Switching off the UV lamps before ending the programme 3.1 Starting the tanning programme 04030 / 0 04030 / 0 02581 / 0 The tanning programme can be started using the coin •= •= During the warm-up phase you can switch on the...
Operation 3.1.3 Surround Cooling 3.1.4 Air conditioning 04006 / 0 04006 / 0 04007 / 0 When a new tanning process is started the surround Pressing button (1) to (-) during tanning reduces the The air conditioning is also switched on when starting a cooling is switched on.
Operation 3.1.5 Power switching Power switching stages UV low pressure lamps-combination (25W) Stage Face Body all on all on all on every 2 every 2 every 2 every 2 04008 / 0 Switching the UV low pressure lamps on/off (25W) The tanning intensity can be changed in 5 steps by switching the UV low pressure lamps (25W) (1) on and off.
Operation 3.1.6 Sound System 04031 / 0 04032 / 0 Switching on and off, channel selection Volume •= •= Different channels can be selected by turning the The volume is turned up or down by turning the knob (1). knob (2). •= The sound system can also be switched off by turning the knob (1).
Maintenance 4.2 Care and maintenance tasks, Cleaning For quick and hygienic cleaning of acrylic surfaces, use the fast-action disinfectant by Sagrotan ® (this is not the same as the commercially available Sagrotan!). To clean the other plastic surfaces, use warm water and a leather. Never use aggressive cleaners, such as commercially available Sagrotan, cleaning agents containing alcohol or essential oils.
Maintenance 4.3 Disconnecting the sunbed from the mains/preventing from switching on 4.3.1 Disconnecting from mains 4.3.2 Preventing from switching on again 01605 / 1 01511 / 0 Danger! Danger! A prohibition sign with the words •= Whenever you need to do work on the sunbed, Accidental switching on again of the sunbed can cause •= ”Work in progress!”...
Maintenance 4.4 Replacing and cleaning lamps (Lamps fitted refer to section 6.3) 04062 / 0 Low pressure lamps •= UV low pressure lamps (1) in canopy, side section and base of the sunbed •= UV low pressure lamps (25W) (2) in the canopy and side section of the sunbed •= Low pressure lamp (3) for decorative lighting in...
Maintenance 4.4.1 Cleaning/replacing UV low pressure lamps in the lower section 04059 / 0 04033 / 0 Removal •= Installation Remove the lamp covers (3) at the head and foot Danger of burns! •= ends. Insert the UV low pressure lamps with the Make sure that the UV low pressure lamps have cooled •= Remove the UV low pressure lamps (4) and...
Maintenance 4.4.2 Cleaning/replacing the UV low pressure lamps in the side section 04011 / 0 04022 / 0 Removal •= Installation Remove the UV low pressure lamps (3) and (4) Danger of burns! •= and change, cleaning with a damp cloth if Insert the UV low pressure lamps with the Make sure that the UV low pressure lamps have cooled necessary.
Maintenance 4.4.3 Cleaning/replacing the UV low pressure lamps in the canopy 04014 / 0 01511 / 0 Removal •= Installation Hold the acrylic panel (1) and unscrew the Danger of burns! •= screws (2) at the head and foot ends with an Insert the UV low pressure lamps with the Make sure that the UV low pressure lamps have cooled Allen key.
Maintenance 4.4.4 Switching decorative lighting on/off changing/cleaning 04013 / 0 04019 / 0 01511 / 0 Removal •= •= Hold the acrylic panel (1) and unscrew the Remove the front 5 UV low pressure lamps . Danger of burns! screws (2) at the head and foot ends with an •= Unscrew the 8 screws (1) of the lamp base (2) Make sure that the UV low pressure lamps have cooled...
Maintenance 4.5 Changing filter mats 4.5.1 Changing filter mats in the lower section 04018 / 0 04020 / 0 Removal •= •= Pull out the filter cassettes (2) to the top. Fold up the filter cassette (4) and change the Danger of damage to sunbed! filter mat (5), cleaning if necessary.
Maintenance 4.5.2 Changing the filter mat in the canopy 4.6 Maintenance of the air conditioning unit 4.6.1 Emptying the overflow tank 04035 / 0 04018 / 0 04024 / 0 •= Removal Removal Unscrew the catch (1) and remove together with •= •= Disconnect sunbed and secure against...
Maintenance 4.6.2 Cleaning the sieve cylinder and lamellas 04018 / 0 04025 / 0 04026 / 0 Removal •= •= Loosen the screws (1) and lift up the suction pipe Remove dirt from the lamellas on the front of the •= Disconnect sunbed and secure against (2).
Maintenance 4.7 Settings 4.7.1 Setting mode 04060 / 0 04061 / 0 04037 / 0 The setting mode enables you to call up operating •= To change values The reference number of the current function and states and make settings (refer to table). Both buttons are required to change values: its current setting will appear in the display ( 2 ) •=...
Fault, cause and remedy Fault, cause and remedy 5.1 Fault table Faults UV lamps do not switch on when the timer/control is actuated UV lamps and fan do not switch on when the timer/control is actuated Decorative lighting does not light Sunbed gets too hot One or more UV low pressure lamps do not light Canopy does not stay in the upper or lower position...
Fault, cause and remedy 5.2 Fault indications in the display 04003 / 0 04030 / 0 Error codes (see the table) appear in the display (1) in •= Elimination of the error is acknowledged by the event of a fault for easier localization of the cause of pressing the STOP/START button (1).
Page 39
Fault, cause and remedy Error code Fault/Error description Remedy refer to section (alternating display) Overflow tank full Empty overflow tank 4.6.1 Fault condensation pump Inform after-sales service. Fault temperature sensor UV low pressure lamps Inform after-sales service. Fault temperature sensor room temperature Inform after-sales service.
Technical data Technical data 6.1 Output Equipment type Ergoline Classic 475 Rated power consumption 8.6 kW without air conditioning: Rated power consumption 9.7 kW with air conditioning: Article number: Refer to Section 2.1 Rated voltage: 400-415V 3N ~ Rated frequency:...
Side section (3) Base (4) 04034 / 0 Lamp type Part no. Radiation equipment UV type Ergoline SD power 25 W UV low pressure lamp 25 W 11122 Ergoline SR turbo power UV low pressure lamps 160 W 10855 Ergoline SD power 25 W UV low pressure lamp...
In the event of malfunctions or should you have a question concerning spare parts, please contact our after-sales service. Our fully-trained personnel will provide you with fast, expert repairs using genuine Ergoline parts. Ergoline GmbH genuine parts are always made in accordance with state-of-the art technology.
Your local sales agency (refer to section 7) will be pleased to help you with the disposal of UV lamps and batteries: •= Inform your local Ergoline agency by telephone or in writing of the number of UV lamps and batteries you wish to dispose of. •= The agency will then inform a waste disposal company to collect the lamps and dispose of them properly.
Appendix 8.3 Ergoline Sound System 8.3.1 Important information on use (GEMA) •= Please observe GEMA regulations when playing background music in the studio. •= For information please get in contact with your District Office responsible for your place of residence or business.
Warranty EU Conformity For a period of 12 months from the date of delivery to the purchaser, Ergoline guarantees that, at Declaration of EC Conformity the time of delivery, the equipment is free of defects that could negate or impair its value or (in conformity with the last amended version) suitability for normal use.