No.
Function
Total operating hours
Remaining operating time for the UV low pressure
lamps
Remaining operating time
UV low pressure lamps (25W)
Remaining operating time for the filter mats
Operating time of the decorative lighting
Fan cool down time
To reset the sunbed to the ex-works setting
Ambient temperature setpoint value
Recycle warm air during fan run-off time
Ex-works setting
To change values
(partly alt. display)
To reset operating hours counters:
Press START/STOP button (4)
To change setting:
- To increase remaining operating time: Press surround cooling button (3) towards (+)
- To reduce remaining operating time: Press surround cooling button (3) towards (-)
To change setting:
- To increase remaining operating time: Press surround cooling button (3) towards (+)
- To reduce remaining operating time: Press surround cooling button (3) towards (-)
To reset value to ex-works setting:
Press START/STOP button (4)
To set to between 1 to 1440 minutes:
- Press surround cooling button (3) towards (+) or (-)
If the maximum value is exceeded, the decorative lighting switches onto permanent
operation. The reading "ON" is shown in the display.
To set to between 1 to 10 minutes:
- Press surround cooling button (3) towards (+) or (-)
The fan cool down time is at least 3 minutes. ""0000" appears in the display.
To reset:
Press START/STOP button (4)
After resetting, the reading "rES" (previously "dEF"). appears in the display.
To set to between 15 to 25 °C:
- Press surround cooling button (3) towards (+) or (-)
To switch recycle on/off:
- on:
Press surround cooling button (3) towards (+)
- off:
Press surround cooling button (3) towards (-)