Structure and function

4.5
Structure and function
4.5.1

TCP gauging as standalone device

Standalone TCP gauging can be installed either on the ceiling of a robot cell or retrofitted as an
addition to the TC 2013.
TCP gauging consists of the following components:
1.
adjusting tip
2.
protective sleeve for adjusting syringe
3.
fibre-optic sensor
4.
fibre-optic
5.
housing
4.5.2

TCP gauging with stand

TCP gauging (1) is mounted on a stand (3), available as a standalone version. A holding angle (2)
is provided to attach the TCP gauging unit on the stand. The TCP gauging unit is screwed and
pinned with the baseplate (4) on the workshop floor or on the floor of the robot cell.
1.
TCP gauging (complete)
2.
holding angle
3.
height-adjustable stand
4.
baseplate
4-4
3HDA000057A8519-001
2
4
1
5
3
1
2
3
4
TCP gauging (BullsEye
®
)