2.7

Maintenance

The TC 2013 torch cleaning station is largely maintenance-free due to the use of high-quality com-
ponents. The frequency of individual checks and maintenance work is guided by the particular
conditions of use of the TC 2013.
We recommend the following maintenance plan to guarantee perfect functioning of the TC 2013.
I
Interval
daily
weekly
monthly
2 annual
*) Mineral oil in accordance with DIN 51524-HLP 32, viscosity 32 cST at 40°C
**) Use only AS 72-K genuine spatter release agent!
Torch cleaner TC 2013
WARNING
Before servicing and maintenance work the TC 2013 is
to be made pressure-less and disconnected from the
power supply and protected against being switched
back on.
Machine part
TSC 2013
Spray nozzle
Milling cutter unit
Maintenance unit
pressure regulator
Maintenance unit
oiler
Release agent container
Cutting knife
Milling cutter
Wire collecting container
Emergency stopping
devices
Maintenance unit
air filter
Cable and connector
V-block TC 2013
Release agent container
3HDA000057A8519-001
Activity
Visual inspection
- Test,
- Clean when required
- Test,
- Clean when required
Check pressure
Check fill-up quantity
- Check fill-up quantity
- Visual inspection on
damage
- Exchange when required
- Clean with brush and
grease lightly
- Check on wear
Check on wear, damage
and firm seating
Regularly empty
Test emergency stopping
devices for function.
Check on pollution
Check for damage and
buckling.
Check on wear
Exchange of the container
Maintenance
Remark
Do not use compressed
air
Values see
Chapter 2.2
Technical data of TC 2013
Mineral oil to DIN 51524-
HLP 32
ABB ordering No
0.743.505.003 **
Grease
ABB ordering No
0.743.505.003 **
2-27