Corrective and preventive maintenance

Figure 3-4 Setting aid for sensors (view from below)
14. Assemble push-in fitting (1) and insert air hose.
15. Screw in screws M5x10 (15) into the housing of the wire cutter but tighten only such that the
wire capture container can be suspended.
16. Carry out function test. In doing so, ensure in particular that compressed air is blown out and
the sensors switch correctly (piston away, clamping / piston back, wire cutting). As a test, also
let a piece of welding wire be cut.
3.7
Corrective and preventive maintenance
Regular corrective and preventive maintenance should be performed to guarantee operation of
the wire cutter. The following activities are recommended:
Maintenance table
Interval
daily
weekly
monthly
3-6
Setting aid
Visual inspection
Empty wire collecting tank
Clean unit of dirt and chips in the area of the blades with a brush. Do not use
compressed air.
Replace blunt cutting plates at the right time.
Regularly check the level of oil in the oiler of the TC 2013 torch cleaner and
top up.
Test emergency stopping devices for function..