Setting - ABB TSC 2013 Assembly Instructions Manual

Torch service center
Table of Contents

Advertisement

Air quality
The compressed air must comply with „class 4" or better in accordance with to ISO 8573-1:2010.
Operating pressure
The operating pressure for the TC 2013 must be at least 5 bar and must not exceed 10 bar. It acts
in the same way for all air consumers on the unit.
The operating pressure is set on the mainte-
nance unit (1) for the complete unit and
should no longer be changed.
The quantity of oil through-flow at the oiler
should be one drop per 6-10 cleaning cycles
and the air motor and the pneumatic cylinders
should be adequately lubricated.
2.4.4

Setting

2.4.4.1
Setting of milling cutter
Cleaning time and milling cutter feed are directly related. If the milling cutter feed is at its maxi-
mum, the cleaning time should be programmed one second longer. Complete cleaning is
achieved in a shorter time.
Milling cutter fed and milling cutter speed are
set on the air exhaust throttle valve (1) .
The cleaning time is controlled through the
cleaning program in the robot control.
The feed rate is approx. 20 mm/sec, i.e.
approx. 2-2.5 sec is to be set for 45 mm
stroke.
The completed stroke is reported by the sen-
sor.
Torch cleaner TC 2013
3HDA000057A8519-001
Assembly and disassembly
1
1
2-13

Advertisement

Table of Contents
loading