Multiple Communication Rate Support
The 2706-P92C-SC and 2706-P94C-SC displays allow you to select serial
communication rates of 9600, 19200, or 38400 bps. The communication rates are
both hardware (dip switches) and software selectable.
For selecting the communication rate using the dip switches, see the
NOTE
section entitled Dip Switch Settings.
The communication rate of the display is set using the InView messaging
software, provided the communication rate dip switches are all off.
To set the communication rate using the messaging software:
1. Highlight the 2706-P9x-SC display you wish to set the communication
rate:
2. Select Set Display Baud Rate under the Tools menu:
Chapter 2: InView System Connectivity
User's Manual 0300277-02 Rev. C
2-7