SHURFLO
WATER BOOST MODULAR FILTRATION SYSTEMS
®
INTRODUCTION
Pentair
Shurflo
has applied its expertise and years of experience in pump technology to provide a safe and reliable
®
®
diaphragm pump. Every Pentair Shurflo pump is 100% tested for proper flow, pressure, and performance before it leaves
the factory. Although this tested design will provide years of trouble-free and economical operation, you should use care in
installing your system.
SYSTEM DESCRIPTION AND FUNCTION
The Pentair Shurflo water boost modular filtration system is designed to integrate both the water boost and water filtration
systems into one easy to install component, thus guaranteeing proper placement of the water boost system in relation to
the filtration system. The system consists of a Pentair Shurflo 8000 diaphragm pump and accumulator tank which function
together to boost the water pressure to the filtration system. The boosted water pressure not only assures an adequate water
supply to the fountain system but maximizes utilization of the filter elements throughout their service life.
The pump, accumulator tank and filtration system are NSF listed.
The system comes mounted on a steel panel which design includes Pentair Shurflo patented slide track design requiring
minimal steps for installation and startup.
FEATURES
• Pentair Shurflo patented slide track design for wall mounting or rack mounting
• NSF listed components
• 115 VAC
• All plumbing connections are located on the upper left of the unit
• City Water Inlet: 3/8" barb
• Water Outlet to Ice Maker Feeder (non-boosted, non-filtered): 3/8" barb
• Water Outlet (2): 3/8" barb
FOODSERVICE
SHURFLO WATER BOOST MODULAR FILTRATION SYSTEM INSTALLATION AND OPERATION GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Pentair SHURFLO WB6-M3-22-003-SS

  • Page 1 SYSTEM DESCRIPTION AND FUNCTION The Pentair Shurflo water boost modular filtration system is designed to integrate both the water boost and water filtration systems into one easy to install component, thus guaranteeing proper placement of the water boost system in relation to the filtration system.
  • Page 2: System Identification

    SYSTEM IDENTIFICATION WATER BOOST MODULAR FILTRATION (WBMF) SYSTEM Water Out Water Out to Carbonator Non-Carb System Ice Maker Tank Pre-charge Water Supply* Main City Valve and Cap Water Inlet City Water In Ball Valve Booster Pump (behind shroud) Pressure Relief Valve Purge Valve Filter Head...
  • Page 3: System Components

    SYSTEM COMPONENTS Filter System Modular filter head design with patented locking system and quick connect couplers for parallel or Design series water flow Inlet Port 3/8" barb Outlet Port 3/8" barb Pressure Gauge 0 –160 psi incremental pressure gauge (measures outlet pressure) Min./Max.
  • Page 4: Performance Data

    PERFORMANCE DATA Important Notice: Read this performance data and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before installing a water treatment system, you have your water supply tested to determine your actual water treatment needs. This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below.
  • Page 5: System Mounting

    Recommended placement of the system is on the left hand side (facing the front of the BIB rack) for easy access to the valve to pre-charge the accumulator tank. • The system is attached to the Pentair Shurflo BIB rack in one simple step by sliding system into top slide track channel and centering system between leg uprights...
  • Page 6 SAFETY WARNING: “Risk of electrical shock.” The pump is supplied with a grounding connector and grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. To prevent electrical shock, disconnect power before initiating any work. In the case of pump failure, the motor housing and/or the pumped fluid may carry high voltage to components normally considered safe.
  • Page 7 21. Check system for water leaks. installations. For additional information regarding the water 22. Turn the outlet globe-valve to the on position. pressure reducer valve please refer to Pentair Shurflo document 911-380. 23. Check for proper operation of icemaker, carbonator and non-carbonated dispense valve operation.
  • Page 8 SYSTEM START-UP AND OPERATIONS CONTINUED Filter Replacement and System Maintenance It is recommended to install new filter cartridges as part of the routine preventive maintenance service or on the event that there is inadequate water outlet supply (see list below) to the dispense system. Inadequate water outlet supply to the dispense system is revealed by one or more of the following symptoms: •...
  • Page 9 23. Turn the purge valve to the OFF position. 28. Check for proper cycling of carbonator and flow rate of non–carbonated valve. SANITIZING It is recommended that all Pentair Shurflo Water Boost Modular Filtration Systems be sanitized under the following ®...
  • Page 10: Troubleshooting Guide

    NOTE: please make sure there is adequate power supply to the system and that the city water supply is turned to the on position as the first steps in troubleshooting this system. NOTE: Recommended installation includes use of the Pentair Shurflo 50 psi inline pressure reducer. Troubleshooting...
  • Page 11 Troubleshooting continued Symptom Probable cause Solution Water filter o-ring on cartridge failed Replace 0-ring on filter cartridge: Kit 94-696-00 Water leaking from bottom of water filter sump O-ring failed between modular filter heads Repair / replace fittings: Kit 94-692-00 Water leaking from schrader valve during Failed bladder Replace bladder: 94-697-00 and pre-charge to proper pressure pre-charge check...
  • Page 12: Limited Warranty

    65.6768.5800 TEL • 65.6737.5149 FAX • CSEVERPURE@PENTAIR.COM EMAIL Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.