6 I/O Interface
6-4

Ethernet Interface

Ethernet port of Sensor Controller is used for EtherNet/IP or Serial (Ethernet) communication. The
Ethernet port can be changed depending on Sensor Controller series. Be sure to check the series you
are attempting to use.
Precautions for Safe Use
• Use only the cables designed specifically for the product. Use of other products may result in
malfunction or damage of the product.
• Always turn OFF the power of the FH-L series Sensor Controller and peripheral devices be-
fore connecting or disconnecting a camera or cable. Connecting the cable with power sup-
plied may result in damage of the camera or peripheral devices.
• Since cables to which bending is frequently applied is easily broken, use the robotic cable
type (bending resistant cable) to prevent damages.
• Do not apply torsion stress to cables. If not, it may cause damage to cables.
• Secure the minimum bending radius of cables. If not, it may cause damage to cables.
Precautions for Correct Use
• Check the following items on the communications cables that are used in the network.
- Are there any breaks?
- Are there any shorts?
- Are there any connector problems?
• When you connect the cable to the communications connectors on devices, firmly insert the
communications cable connector until it locks in place.
• Do not lay the communications cables together with high-voltage lines.
• Do not lay the communications cable near devices that generate noise.
• Do not lay the communications cables in locations subject to high temperatures or high hu-
midity.
• Do not lay the communications cables in locations subject to excessive dirt and dust or to oil
mist or other contaminants.
6-4-1

FH-1000/2000/3000/5000 Series

Ethernet port differ depending on the Sensor Controller series. Refer to the followings, and confirm the
number of ports. FH-1050/3050 (Camera 2ch type); Ethernet port is 1. FH-2050/5050 (Camera 2ch
type) and FH-1050-£0/2050-£0/3050-£0/5050-£0 (Camera 4ch and 8ch type): Ethernet port is 2.
Ethernet port and Ether-
Net/IP port are sharing
use.
Cable
• Connect a straight or cross LAN cable.
6 - 34
FH-1050/FH-3050
FH-1050-10/FH-1050-20/FH-3050-10/FH-3050-20
FH-2000/FH-5000 series
Upper port: Ethernet
port
Lower port: Ethernet
port and EtherNet/IP
port are sharing use.
FH Series Vision System Hardware Setup Manual (Z366-E1)