3 Configuration
3-1-2

FH-L Series

Specification
Series
Type
Model
Controller Type
Parallel IO polarity
Main
Operation
Functions
Mode
Parallel Processing
Number of Connecta-
ble Camera
Supported
Camera
Camera I/F
Possible Number of
Captured Images
Possible Number of
Logging Images to
Sensor Controller
Possible Number of
Scenes
Operating
on UI
Setup
Language
External
Serial Communication
Interface
Ethernet
Communi-
cation
3 - 14
FH-L550
Box type
NPN/PNP (common)
Standard
Yes
Double
Yes
Speed
Multi-input
Non-stop
Yes
adjust-
ment
mode
Multi-line
No
random-
trigger
mode
Yes
2
FH-S ser-
FH-S series cameras except FH-SM21R/SC21R are connectable.
ies cam-
era
FZ-S ser-
All of the FZ-S series cameras are connectable.
ies cam-
era
OMRON I/F
Refer to About Number of Logging Images or About Max. Number of
Loading Images during Multi-input in the Vision System FH/FHV series
User's Manual (Cat.No. Z365).
128
USB
Yes (wired USB and driver is unnecessary type)
Mouse
Touch
Yes (RS-232C/USB connection: FH-MT12)
Panel
Create the processing flow using Flow editing.
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, Ger-
man, French, Spanish, Italian
RS-232C x 1
Protocol
Non-procedure (TCP/UDP)
I/F
1000BASE-T x 1

FH-L Series

Lite Controller
4
FH Series Vision System Hardware Setup Manual (Z366-E1)
FH-L550-10