Fh-1000/2000/3000/5000 Series - Omron Sysmac FH Series Hardware Setup Manual

Vision system
Hide thumbs Also See for Sysmac FH Series:
Table of Contents

Advertisement

5-8-2

FH-1000/2000/3000/5000 Series

Precautions for Correct Use
Ambient Temperature
• Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to +50°C
*1. FH-5000 Series: Surrounding temperature of 0 to 45°C
• Relative humidity of between 35 to 85%
• Do not let the ambient temperature exceed 50°C (122°F).
• Provide a forced-air fan cooling or air conditioning if the ambient temperature is near 50°C
(122°F) so that the ambient temperature never exceeds 50°C (122° F).
Orientation of Product
• For good heat dissipation, install the product only in the position shown below so as not to
block the ventilation holes. Install the product so that the air can flow freely through its cooling
vents.
• Do not install the product in the following positions.
• For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller
away from other devices in the normal floor mounting. For the right and left sides, provide a
clearance of 30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are
also required when mounting multiple Sensor Controllers side by side. For the back mount-
ing, the back-side clearance of 15 [mm] is not required.
Accessibility for Operation and Maintenance
Connect the cable with securing the connector length and the minimum bending radius to the Sensor
Controller.
Connector length
Minimum
bending radius
FH Series Vision System Hardware Setup Manual (Z366-E1)
*1
(-20 to +65°C in storage)
5 Setup and Wiring
5 - 29
5

Advertisement

Table of Contents
loading

Table of Contents