Fh-L Series - Omron Sysmac FH Series Hardware Setup Manual

Vision system
Hide thumbs Also See for Sysmac FH Series:
Table of Contents

Advertisement

5 Setup and Wiring
5-5-3

FH-L Series

Precautions for Safe Use
• Ground
When a base is packed in a camera that will be connected to the Sensor Controller, make
sure to mount the camera using the base. Since the enclosure of the camera main body
made of metals is short-circuited with the internal circuit, the internal circuit might be short-
circuited with FG if no base is used, so that failures or malfunctions may be caused.
• When connect the FH-L series Sensor Controller to the FH-SC12/FH-SM12: 12 mega-
pixels camera
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Camera cable mounting
Connect the cable with securing the connector length and the minimum bending radius to the Sensor
Controller.
Connector length
Minimum
bending radius
Camera Cable
Right-angle Camera Cable
Bend resistant Camera Cable
Bend resistant Right-angle Camera Cable
Long-distance Camera Cable
Long-distance Right-angle Camera Cable
5 - 24
Name
FZ-VS3
FZ-VSL3
FZ-VSB3
FZ-VSLB3
FZ-VS4
FZ-VSL4
Minimum bending
Model
radius
69 [mm]
78 [mm]
FH Series Vision System Hardware Setup Manual (Z366-E1)
Connector length
30 [mm]
42 [mm]