Internal
Open the List file stored inside the instrument.
Recall Inner
File
Export Export the internal List file of the instrument to an external
USB flash drive.
File
The name of the exported list file. The default suf-
Name
fix is .csv, and the file name can only be a string
of numbers.
Edit
Edit list program.
CC / CV
Set the operation mode for list program: CC prior-
ity or CV priority.
Step
The total number of steps included in the List
Count
program.
Step 1
Current value or voltage value setting for Step1.
Value
(The voltage appears when CV priority is se-
lected; the current appears when CC priority is
selected.)
Step 1
Slope value setting for Step1.
Slope
Step 1
Dwell time setting for Step1.
Width
Repeat
Set the number of list file repetitions.
End
Set the running state after the list program is run-
State
ning over.
Last
Normal
Trig Out
Function switch that triggers the signal output. It
is applicable to the scenario of synchronously
controlling multiple units, that is, by connecting
Copyright © Itech Electronic Co., Ltd.
Power Supply Function
Set the name of the recalled List
file.
After the List program finishes run-
ning, the output is kept as the set-
ting in the last step, and the
working mode remains as the set-
ting in the List file.
After the List program finishes run-
ning, the working mode and volt-
age/current output return to the
settings before the List running.
58