If you want to stop testing when the voltage reaches empty voltage, turn on
the UVP function and set the UVP level to the empty voltage value. See
4.5.5 Set Under-Voltage Protection (UVP)
If you want to stop running during the battery simulation test, you can do the fol-
lowing: Press the composite keys [Shift]+[I-set] (Function) on the front panel to
enter the function menu.
At this point, the interface will prompt whether to stop the running of the Func-
tion (FUNCTION STOP?), you can press the Left/Right key to select Yes, then
the current running will be stopped, and the Function menu item will be dis-
played, you can re-enter the Function menu for editing; if No is selected, it
means that the current running will not be stopped, and the main interface of the
system is displayed.
Copyright © Itech Electronic Co., Ltd.
Power Supply Function
for details.