MicroDosage System (MDS) Assembly instructions acc. to EC Dir. 2006/42/EC for partly completed machinery with associated operating instructions for continuous lubrication of high-speed spindles with minimum quantities of oil from 0.5 to 5 mm /min MDR lubricant reservoir MDU micro-metering unit...
Page 4 Table of contents Table of contents Assembly instructions MicroDosage System (MDS) 3. Overview 4.4.2 Assembly drawing with minimum Service SKF microdosage system installation dimensions Information concerning EC Declaration of MDU micro-metering unit 4.4.3 Capillary line connection Conformity and EC Declaration of Incorporation MDR lubricant reservoir designs 4.4.4 Arrangement of capillary lines...
Page 5
Installation and use on spindles Temporary shutdown 4.2.1 Spindle design Permanent shutdown 4.2.2 Lubricant quantity 4.2.3 Filling lubricant ducts in the spindle 8. Maintenance and service General information 5. Design and function Maintenance and repair General information42 Principle of the SKF microdosage system 43...
When used in conformity with their intended Low Voltage Devices 2014/35/EU other machinery to form a machine. Within use, the products supplied by SKF Lubrication RoHS II Directive 2011/65/EU the scope of the EC Directive, commission- Systems Germany GmbH do not reach the...
Explanation of symbols Page 7 Explanation of symbols and signs You will find these symbols, which warn of Instructions placed directly on the product, You are responsible! specific dangers to persons, material assets, or such as: the environment, next to all safety instructions Rotation arrows Please read the assembly and operating in- in these assembly and operating instructions.
Unless specially indicated otherwise, products Assembly, maintenance, and repair work may only be performed on pro- from SKF Lubrication Systems Germany GmbH The definition of qualified personnel and the are not approved for use in potentially explosive prohibition against employing non-qualified ducts that have been de-energized by areas as defined in the ATEX Directive 94/9/EC.
Compressed air hazard improperly or not performed at all Conductors or component connections o Use of non-original SKF components or within the device must not be touched The lubricant reservoir is pressurized with spare parts under any circumstances.
Assembly instructions Page 11 Existing residual risks (residual risk assessment) Residual risk Remedy Life cycle: Assembly Manual filling: • Perform filling of the lubricant reservoir carefully and stop once the “MAX fill level” (sight glass on lubricant discharge from the pressure lubricant reservoir) or electrical max.
Page 12
Page 12 Assembly instructions Residual risk Remedy Life cycle: Setup, retrofit Risk of slipping due to contamination of floor by • Proceed carefully when filling the lubricant reservoir using a filler coupling. spilled or leaked lubricant • Promptly apply suitable binding agents and remove the leaked or spilled lubricant. •...
EC Directive 67/548/EEC, Article 2, Para. 2, the selection of components and the design of chine/system in cooperation with the lubricant may only be filled into SKF centralized lubrication centralized lubrication systems. supplier. When selecting a lubricant, the type systems and components and delivered and/or...
The product described here can be operated You can request an overview of the lubricant using lubricants that meet the specifications in tests offered by SKF from the company's Sales the technical data. department. Note that in rare cases, there may be lubri-...
Assembly instructions Page 15 Approved oils, Table 1 Consult the safety data sheet from the lubri- Lubricant leaking from centralized lubrication cant manufacturer for information regarding systems is a serious hazard. Leaking lubricant Requirement Values transport, storage, processing, and environ- can create risks that may result in physical Recommended 13/10 (ISO 4406)
Page 16 Assembly instructions 3. Overview Overview of the SKF microdosage system Application example of the microdosage system on a machine tool Legend Item Description Chapter 1 MDR lubricant reservoir 1a Electr. fill level switch 4.3.3 1b Max. fill level sight glass 1c Compressed air connection 4.5-10 bar...
Assembly instructions Page 17 Overview of MDU micro-metering unit Components of the MDU micro-metering unit MDU micro-metering unit Item Description Chapter MDU micro-metering unit Power supply LED (green power LED) LED enable signal (yellow enable LED) OI/Chap. 6 Error notification LED (red error LED) LEDs for outlet 1 to outlet 4 (OUT1- OUT4) Push connector/connecting cable for lubricant feed 4.4.
Page 18 Assembly instructions Overview of MDR lubricant reservoir designs Components of an MDR lubricant reservoir MDR lubricant reservoir Examples of various connectivity options, Item Description Chapter area of inlet/outlet/filling MDR lubricant reservoir 4.3.1 Vent plug 4.3.4 Electrical fill level monitoring 4.3.3 Compressed air control valve Compressed air input port...
MDS system must be vented carefully. sequence: and avoid potential hazards. The definition of trained personnel and the A feature of the MDS microdosage system is MDR lubricant reservoir(Chapter 4.3) Attachment of MDR lubricant reservoir prohibition of employing non-qualified per- its ease of use.
These documents can also be down- Follow the safety instructions on the lines. Ensure that no dust particles loaded from the homepage of SKF lubricant's safety data sheet. enter the metering system. Lubrication Systems Germany GmbH.
Assembly instructions Page 21 MDR lubricant reservoir The lubricant reservoir should be installed in a Lubricant and compressed air are separated o Other units must not be damaged by freely accessible area to allow for manual fill- assembly work. from each other by a dividing piston, so a ing and visibility of both sight glasses (fill level compressed air filter is not required.
Page 22 Assembly instructions 4.3.1 Attachment of MDR lubricant reservoir 4.3.2 Assembly drawing with minimum installation dimensions See Figure 1 Mounting dimensions for MDR lubricant reservoir, Fig. 1 Installing the lubricant reservoir Note! • Drill assembly holes (Ø 9 mm, 4x) (1) on To ensure that the microdosage the surface provided by the customer system functions reliably, the pres-...
Assembly instructions Page 23 4.3.3 Electrical fill level indicator 4.3.4 Initial filling and venting of the MDR lubricant reservoir See Figure 2 See Figure 3 • Connect the filling device (e.g., hand pump) (6) and fill up to the start of the maximum To ensure that the micro-metering unit func- •...
Page 24
Page 24 Assembly instructions Venting the MDR, Fig. 3 • Clamp/close the vent hose above the level of the socket wrench. Compressed air feed must not be connected! • Pull off and remove vent hose (9) and socket wrench (3). •...
O-ring (2) lubricant reservoir comes standard with an and the locking claw (5) of the collet (4) and SKF plug connector for a 6 mm tube. The reaches the mechanical stop (3). compressed air line (provided by customer) is connected as described below.
To ensure enough space for maintenance work onto the connector plug (2) of the MDU, to the Figure 5 below. and for possible disassembly of the SKF mi- then align and tighten by hand. crodosage system, ensure that the minimum During assembly and especially when drilling, mounting dimensions (Fig.
Assembly instructions Page 27 4.4.2 Assembly drawing with minimum installation dimensions Assembly drawing of the MDU micro-metering unit, Fig. 5 10,5 SKF Lubrication Systems Germany AG 24 VDC Error Power Enable Enable OUT 1 OUT 2 OUT 3 OUT 4...
Page 28
Page 28 Assembly instructions Note! Electrical connection, Fig. 6 Use functional extra-low voltage with safe isolation according to standard DIN EN 60204-1 / IEC/60204-1. 24 VDC Connecting When establishing the MDU micro- me- coupling (2) Error tering unit’s electrical connection, ensu- Enable re that appropriate measures prevent interference between signals due to...
Assembly instructions Page 29 4.4.3 Capillary line connection See Figure 7 The lubricant feed line must not escape The capillary line is not included with the from the plug connector. MDU and must be ordered separately as an accessory (see “Accessories” chapter). •...
MDR lubricant reservoir must be connected to the metering unit in • Connect main lubricant line to SKF plug • Arrange capillary line (9) to the lubrication such a way that no forces can be transferred connector.
Assembly instructions Page 31 4.5.1 Venting the main lubricant line and MDU micro-metering unit See Figure 9 o Place the oil pan under the MDU, extend immediately attach the loose end of the lubricant line to the plug connector of the the loose end of the main lubricant line Requirements: (connection to MDU) into the pan.
Page 32
This is testing oil what was used in the factory inspection of the MDU. • Use an absorbent cloth to remove discharged oil; remove oil residues using a cloth. SKF Lubrication Systems Germany AG 24 VDC Error Power Enable Enable...
Page 33 Note on the rating plate 4.6.1 MDU rating plate The rating plate of the MDU micro-metering SKF Lubrication Systems Germany GmbH unit and the MDR lubricant reservoir provides Type designation important key data such as type designation Serial number and serial number (or customer number).
Microdosage system (MDS) Operating instructions associated with assembly instructions for continuous lubrication of high-speed spindles with minimum quantities of oil from 0.5 to 5 mm /min...
Caused by the installation of non-original In addition to the operating instructions, SKF components or SKF spare parts general statutory regulations and other o Caused by inappropriate usage regulations for accident prevention o Resulting from improper assembly,...
Page 37 3. Transport, delivery, and storage Lubrication units General information on storage SKF Lubrication Systems Germany GmbH products are packaged in accordance with o Ambient conditions: dry and dust-free o The product(s) can be enveloped in plastic film to provide low-dust storage.
The tube threads indicated in Figure 1 are General suitable for connecting the capillary lines on SW 7 The microdosage system can be used for con- the spindle and bearing. tinuous and highly accurate metering of small quantities of lubricant.
Page 39
4. Assembly Page 39 The lubricant ducts inside a spindle and to the roller bearings, the lubricant should be intro- Lubricant feeding for vertical and horizontal duced into the rolling bearing from both sides bearing lubrication points should meet the fol- mounting position and rotating inner ring, Fig.
Lubrication of bearing running surfaces with Lubricant feeding via outer ring, Fig. 3 a bearing depends on the type of bearing, the microdosage system is more efficient number of rows, width, etc. compared to oil+air lubrication. Almost 100% In principle, the bearing manufacturer should...
4. Assembly Page 41 4.2.3 Filling lubricant ducts in the spindle Within the spindle, there are lubricant ducts 2. The volumetric flow provided by the micro- If the volumetric oil flow in filling mode is not available or only very small volumes are to be through which the lubricant is transported dosage system in filling mode depends on from the connecting points on the spindle to...
The system’s components perform the follow- The system components are connected via the ing tasks: main lubricant line (3). The SKF microdosage system is an intelligent micro-metering system for especially de- manding applications. It feeds lubricant to the MDR lubricant reservoir (1)
See Figure 4 bricant flow at the respective outlet is checked PLC or machine control unit. The MDU contin- The SKF microdosage system consists of two for adherence the defined tolerances according ues metering option despite limitations and main components, the lubricant reservoir to the settings.
Page 44
Page 44 5. Design and function o Clogged line to the lubrication point SKF microdosage system, Fig. 4 o Deviations from the operating temperature range MDU micro-metering unit MDR lubricant reservoir o Error in a metering valve o Error in the flow sensor...
6. Operation Page 45 6. Operation General information The fill level of the lubricant in the lubricant The MDU is subjected to an inspection Note! reservoir should be subjected to visual in- and adjustment using colored lubricant Only fill using clean lubricant and an spection at regular intervals. If the lubricant at the factory.
Page 46 6. Operation Microdosage system parameters Legend to Fig. 5 MDU adjustment elements, Fig. 5 WAF 1 DIP switches S1 to S4 (description in Chapter 4.5.1, adjusting table A) System configuration Quantity reduction of 1:10 S1 off Volumetric flow 0.5 to 5.0 µl/min S1 on Volumetric flow 0.05 to 0.5 µl/min...
6. Operation Page 47 6.2.1 Configuring the system 6.2.2 Determining quantity of lubricant Table A Table B Function/operating mode Switch position Configuration of Rotary switch (S1 to S4) lubricant quantity [Switch position [S1] [S2] [S3] [S4] (SV1 to SV4) Condition on delivery/default setting µl/min Time slot Lubrication system...
Page 48 6. Operation Commissioning/venting the system 6.3.1 Venting the system See Figure 6 Light guides for the LED display are con- See Figures 5 and 7 A requirement for commissioning is that the tained on the inner part of lid of the metering Next, vent the valves and fill the capillary lines.
Page 49
6. Operation Page 49 Example of air dissolved in oil, Fig. 6 o If the switches for multiple outlets are in non-pressurized capillary line. position “F”, the filling procedure is started for the next outlet with the smallest number o The filling procedure must be repeated if immediately after the active outlet is stopped.
Page 50 6. Operation 6.3.2 Filling spindle lubricant ducts See Chapter 4.2.3 Adjustment elements, Fig. 7 To conclude, the lubricant ducts within the spindle are individually filled with lubricant. The procedure is analogous to filling capillary lines. Filling is activated using switch position “F”...
6. Operation Page 51 Calibration of the system See Figures 5 and 7 i.e., when the enable LED (yellow) is lit. During commissioning, it is recommended that 6.4.1 General a manual calibration be performed with up to 3 cycles. This quickly achieves a high level of The MDU has a calibration function that is 6.4.2 Manual calibration accuracy for the volumetric flow under the...
Page 52 6. Operation 6.4.3 Automatic calibration External adjustment of volumetric flow See Figures 8 to 10 Automatic calibration begins during operation Enable signal, Fig. 8 for all active outlets if a corresponding event The machining parameters of machine tool occurs (Table 1, page 44).
Page 53
6. Operation Page 53 To reduce the volumetric flow to one-third or Enable signal, Fig. 9 Enable signal, Fig. 10 one-half (for example), the enable signal must be set to OFF for one third or one-half of the lubrication time (runtime), respectively (see Figure 9 and Fig.
Page 54
Page 54 6. Operation Defining the cycle times: Table C See Table C Cycle times for reducing volumetric flow via the enable signal The time the MDU requires for all outlets to deliver lubricant once is referred to as the cy- Cycle times for enable signal Effective volumetric flow cle time.
To recommission the product, follow the in- structions in the "Assembly instructions" and The product can also be returned to "Commissioning" chapters in these assembly SKF Lubrication Systems Germany instructions. GmbH for disposal, in which case the customer is responsible for reimbursing the costs incurred.
If this occurs, plication. The criteria are machine-specific products are low-maintenance. However, all please contact the Service department of SKF settings, ambient and operating conditions, connections and fittings must be regularly in- Lubrication Systems Germany GmbH for...
8. Maintenance and service Page 57 Maintenance and repair The following maintenance and repair work SKF Lubrication Systems Germany GmbH must be performed on a regular basis: shall not be held liable for damages resulting from improperly performed assembly, mainte- Inspect the main lubricant line and the nance or repair work on the product.
All assembly, maintenance and repair switched off before opening any of the work beyond this scope must be perfor- product's components. med by the Service department of SKF Lubrication Systems Germany GmbH. Danger! Only original spare parts from SKF Centralized lubrication systems are Lubrication Systems Germany GmbH pressurized during operation.
Question Answer What happens if the compressed air The microdosage system typically functions properly even with a somewhat lower compressed air supply for the lubricant reservoir is supply. The automatic calibration compensates for changes in operating parameters such as tempe- below 4 bar and is only 3.5 bar?
Page 60
Yes, this is mandatory. It is absolutely essential to the proper functioning of the the capillary lines? microdosage system that the oil fed from the lubricant reservoir (MDR) is free of air pockets. The system is not completely vented if air pockets are visible in the capillary lines.
10. Technical data Page 61 10. Technical data 10.1 MDU micro-metering unit 10.2 MDR lubricant reservoir Technical data, Table 4 Technical data, Table 5 Designation Designation Temperature range -10°C to +70°C Dimensions (WxLxH) 110 x 313 x 360 mm Mounting position Contents 1 liter Dimensions (WxLxD)
Page 64
All SKF products may be used only for their intended purpose as described in these assembly instructions with associated operating instructions. If assembly/operating instructions are supplied together with the products, they must be read and followed.
Need help?
Do you have a question about the MicroDosage System and is the answer not in the manual?
Questions and answers