Output Specifications

The BOA Spot Vision Sensor provides three (3) dedicated opto-isolated, solid state
relay outputs. One may be used as "strobe" pulse output for an external light source. Or
all three can be used as general purpose outputs.
Specification
Voltage (Vin)
Load
Current
GPO[0:2]
Protection
Fuse
Common pin
Out
Switch Time
ON
OFF
The active polarity of each output is configured in iNspect for BOA Spot application as
detailed on page 48.
To connect with an NPN input source, connect the sensor's output (pin 3, 10 or 11) to
the NPN source input and the sensor's common output (pin 4) to GND. When the
sensor's output turns ON, the opto switch closes and OUTX = 0 (current flows through
load).
To connect with an PNP input source, connect the sensor's output (pin 3, 10 or 11) to
the PNP source input and the sensor's common output (pin 4) to PWR. When the
sensor's output turns ON, the opto switch closes and OUTX = output common.
Output Diagram
PNP Wiring
BOA Spot ID Quick Start
Definition
30 V maximum
160 mA max @ 20°C (drives to OCMN when active)
PTC fuses to 160 mA at 20°C or 100 mA at 70°C
PWR or GND
150 Microseconds typical
50 Microseconds typical
Supply 12-30V
PNP
3
4
Ground
28
Supply 12-30V
NPN Wiring
Ground
Version 1.2; 2017-11-20