Teledyne BOA Spot ID Series Quick Start Manual page 29

Table of Contents

Advertisement

Output Considerations
A hardware output is a signal with a fixed programmed pulse duration and fixed
programmed offset relative to the incoming Trigger signal. Set one output to PASS and
another to FAIL. If processing is not complete when the output decision is scheduled, a
FAIL output will result. This method guarantees a PASS or FAIL output at a predictable
offset for every trigger.
Trigger
Output
Spot processing
A software output is a signal with a fixed pulse output duration but has a variable offset
relative to the Trigger signal. The variability depends on the total processing time per
image. Set one output to PASS and another to FAIL. Software will determine which
output to pulse at the end of processing. This method guarantees a PASS or FAIL
output for every trigger, but does not guarantee timing.
Trigger
Output
Spot processing
BOA Spot ID Quick Start
Pulse Offset
Image
Max Image
Acquisition
Processing
Variable Offset
Image
Max Image
Acquisition
Processing
Trigger Period
Pulse Duration
Flexible application time
Trigger Period
Pulse Duration
Variable
timing
29
Version 1.2; 2017-11-20

Hide quick links: