Ethernet Only Setup
1. Connect the M12-8 male end of the Ethernet cordset (A-BVS-E8S-X) to the M12-8
female connector labeled "LAN" on the sensor.
2. Connect the RJ45 end of the Ethernet cordset to the RJ45 connector labeled "CAM
LAN" on the Panel Link breakout module (A-BVS-PL-100)
3. Connect the RJ45 labeled "LAN" on the breakout module to the controlling PC, PLC
or the factory LAN
4. Connect sensor PWR and GND to the breakout screw terminals labeled "PWR".
NOTE: The trigger button on the PL-100 does not function in this
Setup client PC
Optionally, the IO-PWR cordset (A-BVS2-IO12S-X) can be connected to the PL-100,
to access 2 of the 3 inputs and 2 of the 3 outputs. The trigger button does function
with the IO-PWR cable.
BOA Spot ID Quick Start
A-BVS2-E8S-X
A-BVS-PL-100
Power
21
configuration.
BOA Spot
Version 1.2; 2017-11-20