• FIPS—The LED is green when the FIPS (Federal Information Processing Standards Publications)
security status is operating correctly. If the LED is red, an error has occurred. Restart the Christie
IMB. If the LED remains red, return the Christie IMB to Christie Digital Systems USA Inc.
F
Indicates marriage status. In full power mode, a green LED indicates that the projector is properly
married and encrypted content can be displayed. A red LED indicates marriage is broken and
encrypted content cannot be displayed.
G
Resets the projector electronics. After restarting, the projector returns to its previous power mode.
H
LED status indicators:
• Standby mode—The green LED flashes once per second and the yellow and red LEDs are off.
• Warm up—The green LED flashes three times per second and the yellow and red LEDs are off.
• Power on, lamp on or off—The green LED is solid green and the yellow and red LEDs are off.
• Cool down—The green and yellow LEDs flash three times per second and the red LED is off.
• Notification—The green LED is solid green, the yellow LED flashes once per second, and the red
LED is off.
• Non-critical alarm—The green LED is solid green, the yellow LED flashes three times per second,
and the red LED is off.
• Unacknowledged critical error—The green and yellow LEDs are off and the red LED flashes three
times per second.
• Acknowledged critical error—The green and yellow LEDs are off and the red LED is solid.
I
LED status indicators:
• HUB—The LED is green when FPGA video processing is running correctly, orange when FPGA
video processing is not configured, and red when a failure occurs.
• SMS—The LED is green when the screen management system (SMS) is running correctly, orange
when the SMS or system controller has not booted, and red when a failure occurs.
• INPUT—The LED is green when FPGA video input is running correctly, orange when FPGA is not
configured, and red when a failure occurs.
• Power—The LED is green when the low voltage power supply (LVPS) is operating and red when a
failure has occurred. The LED is not illuminated when the LVPS is not on.
J
Connects the projector to 3D devices.
K
Connects the projector to ingest devices.
L
Connects the projector to external automation or automation devices.
M
Connects the projector to the touch panel (VGA-Out and Screen Power).
N
Management Ethernet port (10/100/1000 base-T) and connects the projector to USB devices,
including the touch panel screen.
O
Two Ethernet ports connecting the projector to network-attached storage (NAS) devices and the
Library Media Server (LMS) network, if applicable. The Media port can also be used for content
transfer.
CP2308-C Installation and Setup Manual
020-102492-01 Rev. 1 (01-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Connecting devices to the projector and establishing communication
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2308

Table of Contents