Program Codes - stertil-KONI SKY-200 Installation, Operation And Maintenance Instructions

Hydraulic vehicle lift
Table of Contents

Advertisement

4
2.
Hold the <overrule> button while turning the main switch to I on the side of the
control box.
3.
Wait for the audio signal, before releasing the <overrule> button.
4.
Select the required code with the <lift> or <lower> button.
5.
Activate the code with the track light button and a point will be displayed next to the
code. Or make the code inactive by operating the track light button once more (point
disappears again).
6.
Push the <overrule> button to exit the program. The system is now operational and
activated codes are stored even during power failures.
The codes can be changed if required, several codes at the same time.

4.7.2 Program codes

Code 60: Programmable absolute height limit
1.
Raise the lift to the required level before making this code active.
2.
If the level should be higher than the actual setting, then first make the setting
inactive (point next to code 60 must be off).
3.
Raise the lift to the required level and now make the setting active again (point next
to 60 must be on).
Code 61: Automatic track lighting switching
This feature will automatically switch on the track lighting above approx. 0,5 m and
switch it off below this limit.
The function of the track light button remains the same if the code is activated.
Above 0,5 m the lights can still be switched on and off.
Code 62: Automatic foot guard
With this code activated, the lift will automatically stop at a defined height when
lowering the lift.
Operation & maintenance instructions (Version H)
Assembly
53
SKY-200/250

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sky-250

Table of Contents