Figure 4.2 Reinforced foundation blocks
Reinforced foundation blocks are only required:
• if there is no suitable concrete floor available (reinforced or not reinforced),
• if the floor is made up of tiles or stones, or if the vehicle lift is installed directly on
the ground,
• with strongly inclined floors to make the base plates level.
When the vehicle lift has to be installed on foundation blocks, the block shown can
be used. Volume = 22.6 qft (0,64 m
Centre line base plate is centre line concrete block.
Maximum ground pressure which can occur here is 95 PSI (67 N/cm
4.3

Securing

Before mounting, follow the instructions as described in
on page
The standard method of securing this vehicle lift is by using the following type of
chemical anchors:
• Anchor rod ASTA M16 x 190, capsule UKA 3 EAP M16 - Torque 60 ft lbs (80 Nm).
However, it is also possible to use the following type of key bolts:
• Key bolts M16 X 150 - Torque 60 ft lbs (80 Nm).