Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Connection Power Unit R6-S
D1...D8
Decoupling diodes (see annex)
DR1,
1) 2)
Commutation reactor / harmonic filter
DR2
DR3
Mains choke
2)
F1...F3
Mains fuses type gR
F4
10 A fuse gG/gL must be monitored (see technical data)
F5
DC fuses type aR must be monitored (see technical data)
F6, F7
DC fuses type aR/gR
G1, G2
Regenerative unit COMBIVERT R6-S
X1A
X1B
X2A
X2B
X2C
G3
Frequency inverter all types (see 4.3.1)
G4
Frequency inverter type B1/B2 (see 4.3.1)
H
Supply of the signalling device
H1
Error message contactor K1 not dropped
H2
Error message contactor K2 not dropped
HF1,
HF2,
Radio interference filter
HF3
K1, K3
Regenerative contactor with auxiliary contact
K4
Line contactor with auxiliary contacts switches on the system.
M
Motor
S2, S3
Realize control release with PLC or pre-charging contactor / -switch
1)
In case of parallel connection of R6-S the total power can be smaller up to 10 % caused by pro-
duction tolerances of the commutation reactor. The impedance voltages uk of the commutation
chokes must be the same in case of parallel connection of R6-S with different sizes.
2)
Parallel connection of the frequency inverter and R6-S causes a circulating current in regenerative
operation. It is depending on the inductance of the mains choke. The entire regenerative power is
75...90 % of the R6-S regenerative power.
Figure 36:
pling diodes.
GB - 86
The cable cross section as well as the DC fuses (see chapter 2.1) must
be dimensioned to the DC rated current of the load (see technical data of
the inverter).
Power circuit terminals
Connection for precharging and switching-on of line contactor K1, K3
Control terminal strip (X2A.12: control release; X2A.17: voltage output)
Connection for synchronization line
Activation of the self-holding of the load shunt relay (K2 internal)
Regenerative operation at parallel operation of up to three R6-S with decou-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert r6

Table of Contents