KEB COMBIVERT R6-S Instruction Manual page 32

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Connection Power Unit R6-S
Wiring of the control release of the connected inverter
A load draw in the DC circuit may be done only when the message „ready" is set. This can be
guaranteed by a series connection of the relay R1 of the R6-S units with the control release of the
connected inverters.
G1, G2 Regenerative unit COMBIVERT R6-S
X2A
G3, G4 Frequency inverter COMBIVERT
X2A
S3, S4
Control release for COMBIVERT
GB - 84
G1
24
X2A
25
26
G2
24
X2A
25
26
Control terminal strip
24
Relay 1 / NO contact
25
Relay 1 / NC contact
26
Relay 1 / switching contact
Control terminal strip
16
Control release
20
24 V output
S3
16
20
S4
16
20
Ready for operation relay
This terminal assignment refers only
to one COMBIVERT