KEB COMBIVERT R6-S Instruction Manual page 24

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Connection of the COMBIVERT R6
Type A1: AC/DC inverter
L1
L2
L3
Type A2: AC/DC inverter
L1
L2
L3
This type can be supplied
by mains and by DC circuit.
The starting current limita-
tion is designed after the
input terminals. When used
as output parallel connected
inverters must have an own
starting current limiting at the
DC voltage input. Observe
the max. load current.
Figure 27:
GB - 76
L1
L2
L3
++
+
L1
--
L2
L3
++
+
L1
L2
L3
--
This type can be supplied
by mains. In consideration
of the DC link capacity the
DC voltage terminals can be
used as output. When used
as input ensure that the
starting current is externally
limited.
General description of input terminals at KEB inverter
Type B1: AC inverter
+
Type B2: AC inverter
Type C1: DC inverter
+PA
+
-
+PA
-
Type C2: DC inverter
+PA
+
-
This type is only a DC in-
verter with starting current
limiting. The DC inverter can
be combined with all other
types in consideration of the
maximum DC link capacity.
++
+
--
++
+
--