ZONE 3 REX STRIKE
TIME:
ALL?: NO
DELAY:
17
The keypad provides a bypass-only option for REX on
Zone 3. When Zone 3 opens from a normal state, only a
bypass occurs: the on-board relay does not activate. This
bypass-only option uses two methods of REX. The first REX
device provides the programmed bypass entry/exit timer.
The second REX unlocks the door.
Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. Range is
5
5-250 seconds. Press any select key to clear the keypad
display and enter the number of seconds. The default is 5.
Arming/Disarming Wait Time
YES
Select the number of seconds (0-9) the keypad should
2
wait to arm and disarm when an Area system displays
ALL? NO YES or a H/S/A system waits during arming only.
If NO or YES, or HOME, SLEEP, or AWAY is not manually
selected before the delay expires, the keypad automatically
selects YES or AWAY. Select zero (0) to disable this feature.
The delay also occurs when a credential is presented for
arming the H/S/A system. Default is 2.
Digital Monitoring Products, Inc | 7000INT Series Installation and Programming Guide