INST ALLA TION GUIDE
Thinline™ LCD Keypads
Models 7060, 7063, 7070, 7073
Aqualite™ LCD Keypads
Models 7060A, 7063A, 7070A, 7073A
Security Command™ LCD Keypads
690/690F, 790/790F, 693/793
�����
�����

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Thinline 7060 and is the answer not in the manual?

Questions and answers

Summary of Contents for DMP Electronics Thinline 7060

  • Page 1 INST ALLA TION GUIDE Thinline™ LCD Keypads Models 7060, 7063, 7070, 7073 Aqualite™ LCD Keypads Models 7060A, 7063A, 7070A, 7073A Security Command™ LCD Keypads 690/690F, 790/790F, 693/793 ����� �����...
  • Page 2 © 2006 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable. This information is subject to change without notice.
  • Page 3: Dmp Keypads

    DMP Keypads The DMP Thinline™, Aqualite™, and Security Command™ LCD Keypads offer flexible features and functionality in stylish design choices. 32-Character Display Power LED ABC PRINTING F R I 2 : 51 AM Armed LED Select Keys COMMAND Key Back Arrow Key Data Entry Digit keys Thinline™/Aqualite™...
  • Page 4: Installing The Keypad

    Installing the Keypad All DMP keypad housings are designed to easily install on any 4” square box, 3-gang switch box, DMP 695 and 696 backbox, or a flat surface. Figure 1 shows the keypad housing base mounting hole locations. Remove the Cover The keypad housing is made up of two parts: the front, which contains the circuit board and keyboard components and the base.
  • Page 5 LCD Keypad Installation Guide...
  • Page 6: Additional Power Supply

    Additional Power Supply If the current draw for all keypads exceeds the panel output, you can provide additional current by adding a Model 505-12 auxiliary power supply. Connect all keypad black ground wires to the power supply negative terminal. Run a jumper wire from the power supply negative terminal to the panel common ground terminal.
  • Page 7: Wiring The 333 Suppressor

    Green/White – Connect Reader Data 0 White – Connect Reader Data 1 Orange – Door Strike Normally Open Gray – Door Strike Common Violet – Door Strike Normally Closed Yellow/White – Zone 4 1K EOL White/Yellow Orange White – Zone 3 Request to Exit (option) 1K EOL White/Orange Red/White...
  • Page 8: Panic Key Options 2-Button Panic Keys

    Zone 2 Door Contact with Soft-Shunt™ (7073/7073A, 793 only) If the door being released by the keypad is protected, you can provide a programmed shunt time by connecting its contact to Zone 2 (White/Red pair) on the keypad and enabling the Soft-Shunt feature. See ZONE 2 SHUNT later in this document.
  • Page 9: 7/0 Panic Keys

    7/0 Panic Keys All keypads also allow the user to initiate an optional Panic alarm by pressing the 7 and 0 (zero) keys simultaneously for one-half (1/2) second. You must enable the 7/0 Panic function in Installer Options in order to use the 7/0 Panic keys.
  • Page 10: Backlighting Brightness

    On all keypads press and hold the Back Arrow (<—) and CMD (COMMAND) keys for two seconds to access User Options. The keypad display changes to SET BRIGHTNESS. Use the COMMAND key to display the next Option or press the Back Arrow to exit the User Options function.
  • Page 11: Entering Alpha Characters

    Entering Alpha Characters To enter an alpha character, press the key that has the desired letter written below it. The keypad display shows the number on that key. To change the number to a letter, press the top row Select key that corresponds to the letter location under the key.
  • Page 12: Programming Keypad Options

    The Keypad Options menu allows you to set the keypad address, select Supervised or Unsupervised mode, change the default keypad message, selectively enable the 2-button Panic keys, Soft-Shunt, Request-to-Exit, and set entry card options. Note: All programming options display on all keypads, however, actual operation for some programming options is restricted to the listed keypads.
  • Page 13 Default Keypad Message DEFAULT KEYPAD Enter a custom message of up to 16 characters to MSG: appear on the keypad display top line whenever that line is not used for any other purpose. Press any Select key to clear the current message and use the data entry keys to enter a new custom display.
  • Page 14 Zone 2 Soft-Shunt Time ZONE 2 SOFTSHUNT (7073/7073A, 793 only) TIME: Enter the number of Soft-Shunt seconds to elapse before the Soft-Shunt timer expires. Range is from 20 to 250 seconds. Press any top row select key to enter the number of seconds. Once the door strike relay is activated, the user has 5 seconds to open the door connected to zone 2.
  • Page 15 Zone 3 Exit (7073/7073A, 793 only) ACTIVATE ZONE 3 Select YES to enable the Request to Exit feature EXIT: NO YES on zone 3. When zone 3 shorts, the keypad relay activates. During this time, the user can open the protected door to start the programmed Soft-Shunt entry/exit timer.
  • Page 16 Custom Card Definitions WIEGAND CODE (7063/7063A, 7073/7073A, 693/793 only) LENGTH: When using a custom credential, enter the total number of bits to be received in Wiegand code including parity bits. Press any top row Select key to enter a number between 0-255 to equal the number of bits.
  • Page 17 User Code Position USER CODE (7063/7063A, 7073/7073A, 693/793 only) POSITION: When using a custom credential, define the User Code start bit position. Press any Select key to enter a number between 0-255. Default is 1. Press COMMAND to save the entry. User Code Length USER CODE (7063/7063A, 7073/7073A, 693/793 only)
  • Page 18 Site Codes 5-8 SITE CODES 5-8 (7063/7063A, 7073/7073A, 693/793 only) > > > > Enter site codes 5-8 (left to right separated by > sign). Press the Select key below the > sign to add, delete, or change the site code and press COMMAND.
  • Page 19 Degraded Mode DEGRADED MODE (7063/7063A, 7073/7073A, 693/793 only) RELAY ALWAYS OFF This option defines the relay action when communication with the panel has not occurred for five seconds. Press any top row Select key to display CHOOSE ACTION. The default is Relay Always Off.
  • Page 20: Accessing Keypad Diagnostics

    Accessing Keypad Diagnostics If necessary, refer to Access the Installer Menu earlier in this document. Keypad Diagnostics (KPD DIAG) KPD KPD The Keypad Diagnostic option allows you to OPT DIAG STOP check the display segments, check the keyboard backlighting, and test individual keys. Press the Select key under KPD DIAG.
  • Page 21: Programming Cards Into The System

    Additional Programming Keypads 7063/7063A, 7073/7073A, and 693/793 The 7063/7063A, 7073/7073A, and 693/793 keypads allow users to present a proximity credential to the built-in proximity reader located in the keypad backlit logo area. Users can also manually enter their user code into the keypad.
  • Page 22: All/Perimeter System Arming And Disarming

    User’s Guide This User’s Guide covers 7063/7063A, 7073/7073A, and 693/793 keypads and contains three different sections: Keypad Arming and Disarming, Keypad Door Strike, and Keypad Entry Delay. All of the examples displayed assume that CLOSING CODE is YES in panel programming. Note: Figures 9 through 12 show the user presenting their card to the keypad.
  • Page 23: Home/Away System Arming And Disarming

    Home/Away System Arming and Disarming Present your card to the reader. If the system is armed, once the card is validated, all areas are disarmed and the keypad displays ALL SYSTEM OFF. If the system is disarmed when you present your card, once the card is validated, HOME SLEEP AWAY displays.
  • Page 24: Fcc Information

    FCC Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • Page 25: Wiring Specifications

    Wiring Specifications When planning a keypad bus installation, keep in mind the following specifications: 1. DMP recommends using 18 or 22-gauge unshielded wire for all keypad and LX-Bus circuits. Do Not use twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity when using 22-gauge wire do not exceed 500 feet.
  • Page 26: Keypad Specifications

    Keypad Specifications LCD Keypad Installation Guide...
  • Page 27: Specifications

    Specifications Operating Voltage 12 VDC Thinline/Aqualite Dimensions 7” W x 5.25” H x 0.5” D Security Command Dimensions 6.5” W x 5” H x 1” D Compatibility All keypads are compatible with all DMP Command Processor™ panels. Listings and Approvals Underwriters Laboratories (UL) Listed Police Connected Burglar Local Burglar...
  • Page 28 LT-0883 (5/06)