7/0 PANIC
ENABLE:
ACTIVATE ZONE 2
BYPASS?
15
7/0 Panic
Press the fourth select key to choose YES, configuring the
NO
7 and 0 keys as two-button panic keys. Select NO to disable
the option. Default is NO.
Activate Zone 2 Bypass
Select YES to activate the zone 2 bypass operation.
NO
Selecting NO allows standard zone operation on Zone 2.
The default is NO. If the door being released by the keypad
is protected (contact installed), a programmable bypass
entry/exit timer can be provided by connecting its contact
wiring to the keypad Zone 2. When the on-board Form C
relay activates and the user opens the door connected
to Zone 2, the zone is delayed for the number of seconds
programmed in ZONE 2 BYPASS TIME allowing the user to
enter/exit during an armed period.
If Zone 2 does not restore (door closed) within the
programmed time, the keypad sounds every other second
during the last ten seconds. If Zone 2 restores prior to the
end of the programmed time, the keypad silences. If the
zone does not restore before the programmed time, the
keypad ends the bypass and indicates the open or short
zone condition to the panel.