Stats Mode - Henny Penny Wendy’s Evolution Elite EEG-153 Service Manual

Reduced oil capacity open gas fryer
Table of Contents

Advertisement

5-5. STATS MODE

ST-1
• Stats Last Reset Date
ST-2
• Fryer Total Running Hours
ST-3
• Left Vat Melt Cycle Hours
ST-4
• Left Vat Cook Cycle Hours
ST-5
• Left Vat Idle Hours
ST-6
• Right Vat Melt Cycle Hours
ST-7
• Right Vat Cook Cycle Hours
ST-8
• Right Vat Idle Hours
ST-9
• Power-Ups Count
ST-10 • Error Counts
ST-11 • Left Vat Heat On Hours
ST-12 • Right Vat Heat On Hours
ST-13 • Highest Left Vat Oil Temperature
ST-14 • Highest Right Vat Oil Temperature
ST-15 • Highest CPU Temperature
May 2012
This mode allows a technician to view advanced information on the
operation of the fryer and controls.
1. Press and hold the
followed by, "SP PROG" and "ENTER CODE" show in the
display.
2. Press the
button 5 times and "STATS" and "ENTER
CODE" flash in the left display.
3. Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
4. "ST-1 STATS LAST RESET ON..." flashes in the left display
and the date shows in the right display. Use the ◄ and ►
buttons to select the steps.
If a bad code is entered, a tone sounds and "BAD CODE"
shows on the display. Wait a few seconds, the controls
revert back to the cook mode, and repeat the above steps.
Press and hold
button at anytime to return to normal
operation.
ST-16 • System RAM Fade Count
ST-17 • Cook RAM Fade Count
ST-18 • Product RAM Fade Count
ST-19 • Stat RAM Fade Count
ST-20 • RAM Data Error Count
ST-21 • Data Total Loss Count
ST-22 • User Intialization Count
ST-23 • Automatic Initialization Count
ST-24 • Cooks Count per Product
ST-25 • Cook Cycle Stop Counts
- "A" = number of stops in the first 30 seconds
- "B" = 0
- "C" = 0
- "D" = complete cook cycles counted
ST-26 • Reset All Stats