6-11. JIB PUMP

6-12. EXPRESS FILTER PC
BOARD
May 2012
This pump keeps the vats filled and is used in the Automatic Inter-
mittant Filter process.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Replacement
1. Remove the right side panel.
2. Using a 1" wrench, loosen both fitting on each side of the pump.
3. Using a Phillip's-head screwdriver, remove the 4 screws
securing the bottom of pump.
4. Disconnect the wires in the rear of the pump and pull assembly
from fryer.
5. Pull fittings from faulty pump and attach the fittings to the new
pump, in the same orientation.
6. Install new pump assembly in fryer, in reverse order and then
reconnect power to fryer.
This electronic board controls the Automatic Intermittant Filtering
process.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Replacement
1. Remove the left side panel.
2. Using a 3/8" socket or nut driver, remove the nuts securing the
cover and remove cover.
3. Pull connectors from PC board.
4. Using a 5/16" socket, remove the 6 nuts securing the board
and remove it from the fryer.
5. Install in reverse order. The control connectors are colored-
coded; Left-Red; Middle-White; Right-Blue.