6-10. FILTER PUMP & MOTOR
Dec. 2018
The 2 most common causes for a fryer not to pump oil are that the
pump is clogged, or the thermal overload switch has been tripped
on the motor. The pump and motor is located on the rear of the
fryer.
To reset the thermal overload switch:
1. Remove the right side panel and locate the pump and motor in
the rear of the fryer. If the motor is hot, allow it to cool for
about 5 minutes.
2. Since it takes some effort to reset the switch, use a tool, such
as a crosshead screwdriver, to press against the reset
button until a "click" is heard.
To remove debris from pump:
1. Loosen the four Allen head screws on the end of
pump and remove the cover. (Removing the bottom rear
panel may help in accessing the set screws.)
For hubmounted filter pump and motors, manufactured after Sep-
tember 2018, removing rotor will break pump body internal seal.
To prevent product damage, DO NOT remove rotor from
pump body.
2. The inside is now exposed leaving a rotor and five teflon
rollers. Clean the rotor and rollers. For filter pump and
motors manufactured after September 2018, rollers may be
removed but rotor must remain in pump body.
3. To reassemble, place rotor on drive shaft (if necessary), and
place roller into rotor.
A small amount of grease might be needed to hold the
bottom roller into place until cover plate is put on. Make
sure O-ring is in proper position on plate.
Indicators, on the side of the two halves of the pump, must
allign together.
6-12