Electrical Connections; Specifications; Particulars - H.C Duke & Son Arby's Electro Freeze Compact Series Operator's Manual With Replacement Parts List

Shake freezer
Table of Contents

Advertisement

2.3

Electrical Connections

1. Always verify electrical
specifications on the data plate (figure
3-2) of each individual freezer. Data plate
specifications will always supersede the
information in this manual.
2. This freezer requires a protected
20 amp 230 volt circuit. Connect the
freezer to a circuit separate from any
other electrical equipment. The power
cord on this freezer connects to a NEMA
6-20R receptacle. See Figure 2-1.
3

Specifications

3.1

Particulars

Width (in/cm)
Height (in/cm)
Depth (in/cm)
Weight (lbs/kg)
Voltage*
Min. Circuit Ampacity
Compressor
185260
ELECTRO FREEZE Shake Model CS704
CAUTION
All materials and
connections must conform
to local requirements and
be in compliance with the
National Electric Code (NEC).
CAUTION
To prevent accidental
electrical shock, a receptacle
with a positive earth ground
is required.
18.4/46.7
58.9/149.7
28.1/71.4
250/113.4
208-230/60/1
1 HP/8000 (BTUH)
.75 kw (Motor)
2.3 kw (Cooling)
3. Supply voltage must be within
±10% of voltage indicated on the
nameplate. Request your local power
company to correct any voltage problem.
4. The control transformer in the
electrical box is factory wired to 208 volts
(red) wire tap for 208V nominal power
supply. If power supply is between 230-
240 volts use 240V (orange) wire tap on
transformer.
Figure 2-1
Beater Motor
Refrigerant
Charge
Cooling
Hopper
20.0
Cylinder
*Contact factory for other voltages.
1/2 HP/.37 kw
R-404a
32.0 oz/.91 kg
Air
20 qts/18.8 liters
7 qts/7.1 liters