MONTHLY
A. Test Head Switch.
The head switch feature is designed
to prevent the beater shaft from being
accidentally activated. It is essential that the
proper operation of this switch be verified on a
routine basis. Use the following instructions to
test for proper operation:
1. Be sure all switches are in the "OFF"
position.
2. Disconnect the main power supply.
3. Remove the dispense head and
beater shaft assembly.
4. Connect the main power supply.
5. Turn the selector switch to the
"CLEAN" position.
Moving parts. Do not place hands
in the freezing cylinder. Severe
personal injury could result.
6.
Look inside the freezing cylinder
toward the rear. The drive shaft coupling
should NOT be turning. Turn the selector
switch to "OFF" and disconnect the main
power supply.
7.
If the drive shaft coupling is turning,
or you are unable to determine whether or
not the shaft is turning, turn the switch to the
"OFF" position, disconnect the main power
supply, and contact your Electro Freeze
distributor for service. DO NOT place the
freezer in service until the problem has been
fixed.
36
CAUTION
— continued
MONTHLY
B. Test Flex Cover Switch.
The flex cover switch feature is designed to
prevent the spinner shaft from being accidentally
activated. It is essential that the proper operation
of this switch be verified on a routine basis.
Use the following instructions to test for proper
operation:
1. Be sure all switches are in the "OFF"
position.
2. Disconnect the main power supply.
3. Remove the flex shaft cover.
4. Connect the main power supply.
5. Turn the selector switch to the "CLEAN"
position.
DO NOT touch or get too close to moving
parts. Clothing, jewelry, hair or other
body parts may become caught in the
machine and result in personal injury.
6. Place a container under the dispensing
plunger.
7.
Push the rinse switch button. The
spinner shaft should NOT be turning. Water will be
dispensed. Turn the selector switch to "OFF" and
disconnect the main power supply.
8.
If the spinner shaft is turning, or you
are unable to determine whether or not the shaft
is turning, turn the selector switch to the "OFF"
position, disconnect the main power supply, and
contact your Electro Freeze distributor for service.
DO NOT place the freezer in service until the
problem has been fixed.