H.C Duke & Son Arby's Electro Freeze Compact Series Operator's Manual With Replacement Parts List page 51

Shake freezer
Table of Contents

Advertisement

13 Troubleshooting Charts
PROBLEM
PROBABLE CAUSE
Product dispenses slowly out of
dispensing head.
Dispensed product too hard.
Freezer runs continually and
product continues to get colder.
Compressor motor does not
operate when dispensing.
Compressor motor does not
operate when dispensing.
185260
ELECTRO FREEZE Shake Model CS704
— continued
1.
No product in hopper.
2.
Product too cold.
3.
Mix feed tube not open.
1.
Torque control erratic or set
too firm
2.
Low suction pressure, refrig-
eration system.
3.
Mix feed tube not open.
1.
Plunger not fully closed.
2.
Starter or relay contact
points stuck.
3.
Torque control not set
properly or faulty.
4.
Suction pressure too low.
1.
Plunger switch defective or
out of adjustment.
2.
Time delay defective.
1.
Plunger switch defective or
out of adjustment.
2.
Time delay defective.
3.
Defective torque control.
REMEDY
1.
Fill hopper.
2.
See "Dispensed product too
hard."
3.
Check mix feed tube setting.
1.
Contact your Electro Freeze
Distributor for service.
2.
Contact your Electro Freeze
Distributor for service.
3.
Check mix feed tube setting.
1.
Close plunger completely.
2.
Contact your Electro Freeze
Distributor for service.
3.
Contact your Electro Freeze
Distributor for service.
4.
Contact your Electro Freeze
Distributor for service.
1.
Contact your Electro Freeze
Distributor for service.
2.
Contact your Electro Freeze
Distributor for service.
1.
Contact your Electro Freeze
Distributor for service.
2.
Contact your Electro Freeze
Distributor for service.
3.
Contact your Electro Freeze
Distributor for service.
41