H.C Duke & Son Arby's Electro Freeze Compact Series Operator's Manual With Replacement Parts List page 25

Shake freezer
Table of Contents

Advertisement

6.2 Disassembly Instructions
1. If there is product in the
freezer refer to Section 9.2, CLOSING
PROCEDURES - DRAINING PRODUCT.
2. Remove flex shaft cover (1).
(Refer to figure 6-2).
3. Place an empty bucket under the
dispensing head.
4. Remove the syrup lines from the
freezer by pressing the metal clip next to
the mix chamber. Twist and pull the mix
chamber (9) off of the head. Remove the
chamber o-ring (10). Remove o-rings (7)
from the quick connect fitting on the mix
chamber.
185260
ELECTRO FREEZE Shake Model CS704
CAUTION
To avoid electrical shock
or contact with moving
parts, make sure all
switches are in the "OFF"
position and that the
main power supply is
disconnected.
CAUTION
To prevent bacteria growth,
remove ALL O-rings when
disassembling for cleaning.
Failure to do so could create
a health hazard.
— continued
5. Remove the actuator rod (16) by
lifting up and swing out.
6. Hold onto the bottom of the
dispense head (5) and release the mixer
shaft (8) from the flexible spinner tube by
lifting up the retainer sleeve on the flex
shaft.
Mixing shaft will fall out of the mix
chamber and could be damaged if
dropped.
FRAGILE. DO NOT DROP.
7. Pull the keeper (4) out of the
head. Remove the pivot post (13). Turn
the handle (11) and remove from plunger
slot.
8. Remove the hand knobs and pull
the head straight out.
9. Remove the plunger (14) from
the head. Remove the mixer bushing (17)
from the plunger.
10. Remove O-rings (2,12,17,18)
from the head (5), pivot post (12) and
plunger (14).
Important:
—continued
15