The degree of protection indicates the suitability of a motor for specific ambient conditions
with regard to humidity as well as the protection against contact and the ingress of foreign
particles. The degrees of protection are classified by EN 60529.
The first code number after the code letters IP indicates the protection against the ingress of
foreign particles and dust. The second code number refers to the protection against the
ingress of humidity.
Code number 1 Degree of protection
0
No protection
1
Protection against the ingress of foreign particles d >
50 mm. No protection in case of deliberate access.
2
Protection against medium-sized foreign particles,
d > 12 mm, keeping away fingers or the like.
3
Protection against small foreign particles d > 2.5 mm.
Keeping away tools, wires or the like.
4
Protection against granular foreign particles, d > 1 mm,
keeping away tools, wire or the like.
5
Protection against dust deposits (dust-protected),
complete protection against contact.
6
Protection against the ingress of dust (dust-proof),
complete protection against contact.
Glossary
Abbreviation
AIE
AIS
OFF state
CCF
EC_FS
EC_SS1
EC_SS2
EC_STO
ON − status
FIT
FMEA
FSoE
GSDML
HFT
Cat.
OSSD
PELV
PL
PM
PP
PS
PWM
SCS
SD−In
SD−Out
SELV
SFF
SIL
210
Code number 2 Degree of protection
0
1
2
3
4
5
6
Meaning
Acknowledge In Error, error acknowledgement
Acknowledge In Stop, restart acknowledgement
Triggered signal status of the safety sensors
Common Cause Error (also β-value)
Error Class Fail Safe
Error-Class Safe Stop 1
Error-Class Safe Stop 2
Error-Class Safe Torque Off Stop 0
Signal status of the safety sensor in normal operation
Failure In Time, 1 FIT = 10-9 Error/h
Failure Mode and Effect Analysis
Fail Safe over EtherCAT, Safety over EtherCAT
Device description file with PROFINET-specific data for integrating the configuration software of a
PROFINET controller.
Hardware Failure Tolerance
Category in accordance with EN ISO 13849-1
Output Signal Switching Device, tested signal output
Protective Extra Low Voltage
Performance Level (in accordance with ISO 13849)
Plus−Minus − switched signal paths
Plus−Plus − switched signal paths
PROFIsafe
Pulse width modulation
Safe Crawling Speed
Safe Digital Input, safe input
Safe Digital Output, safe output
Safety Extra Low Voltage
Safe Failure Fraction
Safety Integrity Level in accordance with IEC 61508
No protection
Protection against vertically dripping water (dripping
water).
Protection against diagonally falling water (dripping
water), 15 ° compared to normal service position.
Protection against spraying water, up to 60 ° from
vertical.
Protection against spraying water from all directions.
Protection against water jets from all directions.
Protection against choppy seas or heavy water jets
(flood protection).