5.5.3 TELEPHONE COMMUNICATORS CONFIGURATION

To.locally.program.basic.parameters.of.he.system,.follow.the.instructions.below:.
1.. Select.the.desired.system.from.Plants list and.press.the.button.Communicators..
.. On.the.display.appears.Communicators, that allows to configure the PSTN telephone communicator and the GSM module.
The following parameters are configurable:
Phone options:
Communicators,. where. it. is. possible. to. indicate. if. in. the. control. panel. are. installed. the. PSTn. telephone. communicator,. the. GSM.
module or both of them. If both of them are installed, it is also possible to select, with priority, which one must be used first.
Phone call check,.that.allows.to.set.the.following.parameters:
Answer control,.that.recognizes.the.call.signal,.after.the.number.has.been.dialled..If.the.answer.check.is.enabled,.the.communicator.
waits.until.the.called.number.answers,.before.playing.the.alarm.vocal.message.(if.the.call.signal.is.not.recognized,.the.alarm.vocal.
message is played anyway, after some seconds from the end of the dialled telephone number). If disabled, the vocal message is
played..seconds.after.the.the.telephone.number.has.been.dialled..
Tones control, if enabled, it dials the number only after the dial tone has been detected; if disabled, it enters the number 3 seconds
after the line has been seized. If the GSM communicator is installed, it enables the field test before the calls cycle.
Incoming call rings,.that.allows.to.set.the.rings.number.before.the.control.panel.answers.an.incoming.call..If.the.rings.number.is.set.
to."0",.incoming.calls.are.ignored..
Phone line test.tests,.allows.to.select.one.of.the.following.options:.
Disabled,.disables.the.test.used.to.check.the.telephone.line.correct.operation..
Enabled without SAG alarm, enables the automatic test for telephone line check (failure or no line). The test is performed each time