the system is activated/deactivated (also partially). If the test is unsuccessful, no tamper alarm is generated.
Enabled with SAG alarm, enables the automatic test for telephone line check (failure or no line). The test is performed each time the
system is armed/disarmed (also partially). If the test is unsuccessful, is generated not only the failure signalling, but also the tamper
alarm..
Phone numbers:
Phone number,.is.the.telephone.number.to.be.used..The.number.can.be.composed.by.1.digits.max..
Call type, used to indicate if the alarm message must be sent only as vocal message (Voice), as vocal and SMS (Voice + SMS) or
numeric, if addressed to an alarm reception centre (IDP, ADF or SIA, according to the protocol used by the alarm reception centre).
SMS.messages.will.be.sent.only.if.the.GSM.module.is.present.and.has.priority,.and.numeric.calls.to.alarm.reception.centres.only.if.the.
PSTn.module.is.present.and.has.priority..
As.last.step,.select.the.alarm.events.associated.to.the.telephone.number,.that.will.generate.the.alarm.message.sending..
.
34
DS1061-015B

Hide quick links: