Exit.from.programming.procedure; System Configuration Via Software; Usb.interface.mounting.and.pc.connection; Basic.parameters.programming - urmet domus 1061/004 Installation And Programming Manual

Multifunction control panel
Table of Contents

Advertisement

How to set the auxiliary input for the rolling shutter detector
1.. Disarm.the.system..
.. Put.the.keypad.rotary.switch.on."F"..
3.. Press.twice.the.keypad."X" button; a confirmation beep will be emitted.
4. Put back again the keypad rotary switch on its original address (position "0", "1", "2" or "3").
5.4.14 EXIT FROM PROGRAMMING PROCEDURE
To exit from the programming procedure, it is sufficient to go to the main level of menus tree, by pressing ESC button repeatedly and then keep
ESC button pressed for 3 seconds. The LCD display turns off and the parameters configured until that time will be stored in the control panel.

5.5 SYSTEM CONFIGURATION VIA SOFTWARE

Using.a.PC.provided.with.Urmet.EasyPro.software,.it.is.possible.to.program.more.easily.1061/004.and.1061/006.control.panels..To.do.it,.connect.
the PC to the control panel via the USB 2.0 interface. With the same software it is possible to access to further PSTN telephone communicator
and GSM module configuration parameters. In this way it is possible to perform a more detailed customization than the one obtained with the
control.panel.programming.menus.
5.5.1 USB INTERFACE MOUNTING AND PC CONNECTION
To.mount.the.USB.interface.and.connect.the.PC,.follow.the.instructions.below:.
1.. If.necessary,.put.the.system.in.maintenance.mode,.as.described.in.paragraph.7.1.Maintenance.procedure..
.. Connect.the.USB.interface.to.the.motherboard,.as.shown.in.the.following.diagram..
Figure 30 – USB 2.0 interface connection diagram
3... Connect.the.PC.to.the.interface,.using.the.provided.USB.cable..
At.the.end.of.the.programming.procedure,.simply.disconnect.the.USB.interface.from.the.control.panel.motherboard..
.
WARNING:.It is assumed that the user is able to use the EasyPro software. For sections not described in this manual (for example, the connection
and its parameters, creation of a new system, etc.), refer to the software user manual.
5.5.2 BASIC PARAMETERS PROGRAMMING.
To.program.locally.system.basic.parameters,.follow.the.instructions.below:.
1.. Select.the.desired.system.from.Plants list.and.press.the.button.Settings.