10. FACTORY SETTINGS

To reset the control panel to factory settings (reset), follow the procedure below:
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Keep.the.arrow.button.pressed.for.10s.
4.. On.the.display.appears.the.message.
5.. Press.OK.button.
6.. On.the.display.appears.the.software.version.and.then.it.blinks.
7.. Insert.a.Master.key.or.enter.a.Master.code.and.keep.on.programming.
§
The reset to factory parameters deletes ALL the settings previously present.
CONTROL PANEL UNIT PARAMETERS
Connection.mode.of.inputs.and.tamper.line
Inputs.self.by-pass
Inputs.types
Inputs configuration
Output.1
Output.
Inputs.association
Auxiliary inputs association (Keypads)
Intrusion.alarm.duration
Entry.time
Exit.time
Mains.fail.for.30Vac.mains.fail.alarm.activation
Technological.alarm.duration
Keys.association
Codes.association
TELEPHONE COMMUNICATORS PARAMETERS
PSTn.module
GSM.module
Answer.check
Tones.check
Rings.number.for.answer.to.incoming.calls
Telephone.line.automatic.tests
Alarms/telephone.numbers.association
SMS.sending
Type.of.message
DS1061-015B
(reset default).
.
Normally closed (NC) (programmable with JP1)
Disabled (programmable with JP2)
Line 1 delayed (not programmable)
Lines 2-6 immediate (not programmable)
Intrusion
Intrusion/tamper.alarm
Failure/Low.battery.alarm
All.associated.to.partition.A
All associated to partition A (not programmable)
60.seconds
30.seconds
30.seconds
1.hour.
30.seconds
To.all.partitions
To.all.partitions
Disabled
Disabled
Disabled
Disabled
0
Disabled
no
Disabled
Vocal
41