Detector; Detector.addition; Detector.deleting; Detector.replacement - urmet domus 1061/004 Installation And Programming Manual

Multifunction control panel
Table of Contents

Advertisement

7.4 DETECTOR

.
7.4.1 DETECTOR ADDITION
To.add.a.detector.to.a.control.panel.input,.follow.the.instructions.below:.
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Unpower.the.control.panel.
4.. Disconnect.the.control.panel.backup.battery..
5.. Add.the.new.detector,.following.its.instructions..If.the.input.to.be.used.has.already.other.detectors.connected,.the.new.device.must.be.
compatible.with.the.existing.ones..For.further.information,.refer.to.instructions.in.chapter.4..
6.. Connect.again.the.backup.battery.and.power.again.the.control.panel..
7. If the new detector has been connected to a unused input, perform the input configuration.
8.. Close.the.control.panel.to.exit.from.the.maintenance.procedure.
7.4.2 DETECTOR DELETING
To.delete.a.detector,.follow.the.instructions.below:
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Unpower.the.control.panel.
4.. Disconnect.the.control.panel.backup.battery..
5.. Remove.the.detector.
6.. Connect.again.the.backup.battery.and.power.again.the.control.panel.
7.. If.the.detector.was.the.only.connected.to.the.input,.program.the.input.as."not.used"..
8.. Close.the.control.panel.to.exit.from.the.maintenance.procedure.
7.4.3 DETECTOR REPLACEMENT
To replace a detector with an equivalent device, follow the instructions below:
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Unpower.the.control.panel.
4.. Disconnect.the.control.panel.backup.battery..
5.. Replace.the.old.detector.with.the.new.one.
6.. Connect.again.the.backup.battery.and.power.again.the.control.panel.
7.. Close.the.control.panel.to.exit.from.the.maintenance.procedure.
7.5 ADDITION OF A CONTROL PANEL OPTIONAL DEVICE
.
To.add.an.optional.device.to.the.control.panel,.follow.the.instructions.below:.
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Unpower.the.control.panel.
4.. Disconnect.the.control.panel.backup.battery.
5.. Add.the.optional.device.in.the.control.panel,.by.following.instructions.in.chapter.4.
6.. Connect.again.the.backup.battery.and.power.again.the.control.panel.
7.. Program.the.functions.available.with.the.new.option.
8.. Close.the.control.panel.to.exit.from.the.maintenance.procedure.
7.6 BATTERY REPLACEMENT
To.replace.the.control.panel.backup.battery,.follow.the.instructions.below:.
1.. Activate.the.system.maintenance.mode.(see.paragraph.7.1 Maintenance procedure).
.. Open.the.control.panel.
3.. Unpower.the.control.panel.
4.. Disconnect.the.control.panel.backup.battery.
5.. Replace.the.old.battery.with.a.new.one,.with.same.technical.characteristics.
6.. Connect.again.the.backup.battery.and.power.again.the.control.panel.
7.. Close.the.control.panel.to.exit.from.the.maintenance.procedure.
WARNING:. Batteries are special waste material and their disposal is regulated by precise legal provisions; they must be taken to specific
collection centres.

7.7 CLEANING

.
For.devices.cleaning,.use.a.dry.cloth.