Laser Driver Principle And Error Codes - Barco F70 Service Manual

Hide thumbs Also See for F70:
Table of Contents

Advertisement

GP7 system functional description
12V
12V
Psu
12V
12V_Standby
PSU Enable / feedback Safety loop
Image 5-6

5.7 Laser driver Principle and error codes

There are two identical laser driver PCB's, defined as Board 1 and Board 0, where Board 0 is the lower board,
and Board 1 is the upper board.
Each board has four outputs, named 0 – 3, where output 0 – 2 are used in the F70 projector.
This drives the laser cluster, which consist of six laser banks. (3 + 3).
See chapter 5.7.1 for a block diagram for the laser and drivers.
For monitoring the status / condition of the laser driver module, there are NTC's connected to each laser bank,
and on each driver output on the laser driver boards. The software will monitor the data from this NTC's
continuously, and by an error, a failure message will occur, that defines the error.
The NTC's on the Laser driver board are defines as "heatsink" in the error message string, and the NTC's on
the laser banks is defined as "bank" in the error message string.
This means that error message can look like this:
#e20400 environment.laser.board1.bank0.error input...
Meaning that there are registered a temperature error in bank0 in the left Cluster
Other examples of error messages:
#e20400 environment.laser.board1.bank4.error input...
Meaning there is a temp error in the right Cluster #e20400 environment.laser.board1.bank1.error input...
Meaning that there is a temperature error in the lower laser driver board.
#e20400 environment.laser.board0.heatsink0.error input...
#e20400 environment.laser.board1.heatsink1.error input...
Meaning that there is a temp error in the upper laser driver board.
So; the clue in identifying source failure from those messages is to identify the board number, whether it is a
heatsink or bank mentioned, and which number they have.
See also the error code/failure matrix, and the block diagram for an overview of the system.
34
723–0018 /02
F70
TEC main
Dew point sensor
Thermal hub board
Main board
Enable Laser
Enable PSU
FPGA (DLP)
Enable
Laser driver
[Hardware threshold 84°C°C]
(NOT IN use for F70/F90Captains safety / not required if pwm range will cover safety temperatures)
X5
X5
Safety switch laser housing left
Bimetallic switch [NC 90°C] DMD cloldplate
Switch 1 bottom cover
Switch 2 bottom cover
X12
Laser
X12
NTC [TM lasers X6pcs.]
Fan Radiator
PUMP liquid cooling
Bimetallic switch 1 [NC 90°C] optical path
Bimetallic switch 1 [NC 90°C] optical path

Hide quick links:

Advertisement

Table of Contents
loading