C. TROUBLESHOOTING
C.1 Error codes
Overview
When the error code is preceded by a '-' sign, then the error means a real error for the projector.
When the error code is preceded by a '+' sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
Description
code
1000
Wrong lamp
parameters
1017
1499
1498
1699
Formatter
busy
1698
Formatter
address
1697
Formatter init
failed
1696
Formatter ctrl
init failed
1695
Red form.
start failed
1694
Green form.
start failed
1693
Blue form.
start failed
1692
Form.
PWRGood
2000
No lps
detected
2001
Mains voltage
too low
2002
Lamp start
failed
2003
Main voltage
too high
2004
Lamp goes out
2005
Lamp stop
failed
R5976986 FLM HD18 01/09/2006
Error
Warn-
Caused by
ing
-
Yes
Wrong lamp/ no communication
with lamp
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with red
formatter
-
Yes
no communication with green
formatter
-
Yes
no communication with blue
formatter
-
Yes
formatter 'Power Good' signal not
OK
-
Yes
no communication with lamp power
supply
-
Yes
mains voltage too low
-
Yes
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
-
Yes
mains voltage too high
-
Yes
-
Yes
C. Troubleshooting
Action
Check lamp type
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
Call qualified service engineer
Call qualified service engineer