Barco F70 Service Manual page 97

Hide thumbs Also See for F70:
Table of Contents

Advertisement

Code E9000300: "PSU ThermalHub low limit reached" (Error)
Situation
Potential malfunction of the
PSU: Thermal Hub 12V
voltage to low.
Code E9000301: "PSU ThermalHub high limit reached" (Error)
Situation
Potential malfunction of the
PSU: Thermal Hub 12V
voltage to high.
Code E9000400: "PSU Fan low limit reached" (Error)
Situation
Potential malfunction of the
PSU: Fan not spinning.
Code E9000501: "PSU Heatsink1 temperature exceeded" (Error)
Situation
Potential malfunction of the
PSU: Heatsink1 temp too high.
Code E9000601: "PSU Heatsink2 temperature exceeded" (Error)
Situation
Potential malfunction of the
PSU: Heatsink2 temp too high.
Code L80000: "Illumination laser was switched off unexpectedly" (Error)
Situation
Light Source switched off due
to other Light Source related
errors
Code L80001: "Illumination laser communication error" (Error)
Situation
Communication error with the
light source or one of its linked
components
Solution
Replace the PSU. See service procedure .
Solution
Replace the PSU. See service procedure .
Solution
Verify if the fan is not blocked.
Check the fan wiring.
Solution
Verify if the fan is not blocked.
Check the fan wiring.
Replace the PSU. See service procedure .
Solution
Verify if the fan is not blocked.
Check the fan wiring.
Replace the PSU. See service procedure .
Solution
This error will appear together with other errors. Solve those errors first.
Solution
This error will appear together with other communication errors. Solve
those errors first.