Image 14-5
When this menu is entered, the following things happen:
The resolution for the unit changes to 4K-UHD, and the XPS actuator are switched on.
The Xpr-cross test picture occurs on the screen.
Select the Resonance slider, and set the Resonance to the same value as on the new XPS actuator.
Observe the cross pattern in the test picture.
You have to be close up to the screen to observe this.
The XPR cross test picture is only available when the projector is in "Desktop Front" configuration.
Ideally, the inner cross shall be positioned in the middle of the outer cross. If not, adjust the "Gain" slider, until
the center cross is exactly in the center of the outer cross.
Exit the Pixel Shift Menu.
XPS actuator
723–0018 /02
F70